Installation Instructions

EN
5
2.3 Installation niche features: Professional
Series
A - area to be left clear for the anti-tipping brackets
Minimum Niche Height
2134 mm (84”)
Minimum Niche Width
36”: 902 mm (35 1/2”)
24”: 602 mm (23 3/4”)
Door Swing Clearance
36”: 1470 mm (57 7/8”)
24”: 1170 mm (46”)
Door Opening Angle
105°
Width
36”: 899 mm (35 3/8”)
24”: 599 mm (23 5/8”)
Height
2120 mm (83 1/2”) + 25 mm (1”)
Depth with door
635 mm (25 ”)
Minimum distance from the wall (hinge side)
36”: 230 mm (9”)
24”: 160 mm (6 1/4”)
IMPORTANT
If the units are to be installed inside a niche or within an
enclosed structure, it is necessary to design a ventilation
shaft at the back of the niche to assure proper ventilation
at the back of the unit.
Cross-sectional chimney ventilation area should equal
200cm² (31in²)
1016 (40”)
36: 1470 (57 ⅞”)
24: 1170 (46”)
560 (22”)
75 (3”)
36: 899 (35 ”)
30: 749 (29 ½”)
24: 599 (23 ”)
10 (⅜”)
58 (2 ¼”)
105°
635 (25”)
36: 230 (9”)
24: 160 (6 ¼”)
A A
140 (5 ½”) 140 (5 ½”)
100 (4”)
100 (4”)
min 2134 (84”)
36: 902 (35 ½”)
24: 602 (23 ¾”)
560 (22”)
2120 (83 ½”) +25 (1”)
613 (24 ⅛”)+25 (1”)
635 (25”)
693 (27 ¼”)
516 (20 ⅜”)
1296 (50”)
195 (7 ⅝”)
8 (⅜”)
8 (⅜”)
97 (3 ⅞”)
+ 25 (1”)
min 10 (⅜”)
min 50 (2”)