Datasheet

Page 18/19
ACC-EMP-N-dual
Order No.: 600499
Description:
This overvoltage protector is used to largely prevent overvoltages from the outside from harming the
electronics and the network, e.g. in the case of a thunderstorm. It is designed for up to 6 GHz and can
therefore easily be used for systems from 2 GHz to 5 GHz. With its N plug and N jack, it can be placed
between the RTNC-N cable and other N cables. The overvoltage protector should be mounted at the transition
point to the building and must be sufficiently earthed.
Insertion loss: 0.4 dB at 2.4 GHz, 0.7 dB at 5.5 GHz
0 1 2 3 4 5 6
Frequency (GHz)
Funkwerk N plug to N B/H jack surge arrester
-2
-1.5
-1
-0.5
0
Insertion Loss[S21](dB)
5.88 GHz
-0.423
2.5 GHz
-0.236
DB(|S[2,1]|)
SA13B2
0 1 2 3 4 5 6
Frequency (GHz)
Funkwerk N plug to N B/H jack surge arrester
1
1.5
2
VSWR [S11]
5.88 GHz
1.15
2.39 GHz
1.18
VSWR[1]
SA13B2
0 1 2 3 4 5 6
Frequency (GHz)
Funkwerk N plug to N B/H jack surge arrester
-2
-1.5
-1
-0.5
0
Insertion Loss[S12](dB)
5.88 GHz
-0.41
2.49 GHz
-0.18
DB(|S[1,2]|)
SA13B2
0 1 2 3 4 5 6
Frequency (GHz)
Funkwerk N plug to N B/H jack surge arrester
1
1.5
2
VSWR[S22]
5.88 GHz
1.25
2.4 GHz
1.18
VSWR[2]
SA13B2