Operator's Manual

5. INSTALLATION AND INITIAL SETTINGS
5-10
Output PGNs
5.4 Post Installation Initial Settings (Initialization
Menu)
After mounting and wiring are completed, when the CAN bus/NMEA2000 network is
turned on, the FI-70 will start up. If this is the first time the FI-70 has been powered,
the [Initialization] menu is displayed. Set the language, units of measurement and your
ship type in this menu.
Follow the procedure below to set up the FI-70. After completion of this process, set
up Data Sources (See section 4.8) and IF-NMEAFI (See section 4.6.1), as necessary.
1. [Language] is selected, press the function key.
The FI-70 supports the following languages:
2. Press the software keys to select the appropriate language, then press the func-
tion key to apply the setting.
3. Press the software keys to select [Units], then press the function key.
4. Select the appropriate unit to adjust, then press the function key to display the
available options. Options are outlined in the table on the following page.
PGN Description PGN Description
059392 ISO Acknowledgment 059904 ISO Request
060928 ISO Address Claim 061184 Self Test Group Function
126208 NMEA - Request/Acknowledge Group
Function
126464 Receive/Transmit PGN's Group
Function
126720 Memory Group Function/Request
Group Function/GMM Message
126993 Heartbeat
126996 Product Information 130314 Actual Pressure
130816 Proprietary PGN (Furuno) 130821 Proprietary PGN (Furuno)
130822 Proprietary PGN (Furuno) 130823 Proprietary PGN (Furuno)
130825 Proprietary PGN (Furuno) 130841 Proprietary PGN (Furuno)