3. WIRING
3-2
3.2 Transducer
Connect the transducer cable to the XDR port.
Transducer and sensor
Use the optional conversion cable (02S4147) to connect the optional speed/tempera-
ture sensor and the transducer to the XDR port. Refer to Operator’s Manual in detail.
Matching box (option, required for 1 kW transducer)
The optional matching box (Type: MB-1100, Code No.: 000-041-353) is required to
connect the optional transducers 50B-6, 50B-6B, 200B-5S, 50/200-1T and 50/200-
12M.
*: With 10P connector cable
**: For connecting two transducers
3.3 External Equipment
About CAN bus connections
CAN bus is a communication protocol that shares multiple data and signals through a
single backbone cable. You can simply connect any CAN bus devices onto the back-
bone cable to expand your network onboard. With CAN bus, IDs are assigned to all
the devices in the network, and the status of each sensor in the network can be de-
tected. All the CAN bus devices can be incorporated into the NMEA2000 network. For
detailed information about CAN bus wiring, see “Furuno CAN bus Network Design
Guide” (Type: TIE-00170) on Tech-Net), or contact your dealer.
Part Type Code no. Qty
Matching Box* MB-1100 000-041-000 1
Crimp-on Lug FV1.25-3 (LF) 000-116-756-10 6
Cord Lock** NC-1 000-168-230-10 1
Jumper block setting
J2: No output reduction (default)
J1: Output reduction
Transducer
50B-6/6B
50kHz
200kHz
SHIELD
BLK
RED
TB2
1
2
3
4
5
J2 J1
WHT
3
2
1
BLK
TB1
02P6348
BLK
RED
Connect 10P
connector to
XDR port on
rear of
display unit.
Green
(shield)
Detach grommet;
attach cord lock.
Transducer
200B-5S
Vinyl Sheath
Taping
Shrink Tubing
Shield
Crimp-on Lug
FV1.25-3 (LF)