Operator's Manual

68
User Controls
OSD Menu Functions
IND100064-38
Service
Will show various technical and unit related information, such as; Firmware versions, Elapsed Time,
Internal Temperature, Fault Status and activation for the internal Test Pattern image useful for trouble-
shooting. Some of these functions are static information while others are accessible. Whenever you are in
contact with helpdesk or service personnel, they might require you to read back some of these values in
order to precisely pinpoint any problem/question you should have with the unit or its functionality.
Information blocks as follows:
“GEV Firmware Rev” = Displays the rmware version of the GEV videocontroller.
Example: “GEVHD-24 120120V2”
“CYP Firmware Rev” = Displays the rmware version of the touch enabled buttons.
Example: “120119R0V01”
“Ethernet Firmware Rev” = Displays the rmware version of the Ethernet controller.
Example: “E121003V1”
“Elapsed Time” = Shows the time elapsed in hours since rst-time power on.
Example: “180”
“Current Temperature” = Shows the internal temperature measured by onchip sensor.
Example: “+027.0 C”, in Celcius Degrees.
|---2---
Service - Fault Status
Will show detected Fault Staus by measuring various internal values for “DVI Chip”, “NVRAM”,
“DDC” and “TMP Sensor” during operation. Status is stated as either “OK” or “FAULT”. The contents
of this submenu is listed below.
Fault Status as follows:
“DVI Chip” = Status for on-board Digital Visual Interface graphics chip processor.
“NVRAM” = Status for Non-volatile random-access memory,
used to store parameters and settings.
“Ethernet” = Status for Ethernet/LAN communication chip controller.
“GDC” = Status for Glass Display Control™ (GDC) touch button controller.
“TMP Sensor” = Status for internal temperature measured by on-chip sensor.