Operator's Manual

9. INSTALLATION
9-2
9.2 Installation
Mounting considerations
The remote display can be installed on a desktop, on the underside of a table, or flush
mounted in a panel. When you select a mounting location, remember the following
points:
The nominal viewing distance for the display unit is 0.6 m. Select a suitable mount-
ing location considering that distance.
Locate the remote display away from exhaust pipes and vents.
Select an installation location that is well ventilated.
Locate the remote display where shock and vibration are minimal.
Locate the remote display away from equipment which generates the electromag-
netic fields like a motor or generator.
Allow enough maintenance space at the sides and rear of the remote display and
leave enough slack in cables to facilitate maintenance and servicing.
Observe the compass safe distances (see page ii) to prevent the interference to a
magnetic compass.
Flush mounting
See the outline drawing in the back of this manual.
1. Make a cutout in the mounting location using the template.
2. Make four pilot holes for self-tapping screws (3x20) in the mounting location.
3. Remove the hanger assembly from the remote display. Discard the hanger as-
sembly.
4. Remove the front panel from the remote display by unfastening the catches at the
rear of the panel by hands, in the order shown in the figure below.
127 ± 0.5 (5.00”)
130 ± 1 (5.12”)
110 ± 1 (4.33”)
110 ± 0.5 (4.33”)
Pilot hole (4 places)
4-R12
1
2
3
4
8
7
6
5