Operator's Manual
9. INSTALLATION
9-10
Note 1: >: The priority of the left sentence is higher than the one of right sentence.
Note 2: CAN bus>NMEA 0183
Output signal
Note: When Mix is active, the inputted NMEA0183 data is outputted in NMEA0183 for-
mat.
Humidity CAN bus 130311 (Environmental Parameters)
NMEA 0183 MDA
Rudder CAN bus 127245 (Rudder)
NMEA 0183 RSA
Engine CAN bus 127497 (Trip Parameters, Engine),
127488 (Engine Parameters, Rapid
Update), 127489 (Engine Parameters,
Dynamic)
NMEA 0183 -
Current (tide) CAN bus -
NMEA 0183 CUR > VDR
Data Port Sentence, PGN (Title)
Depth CAN→0183 128267→DPT
0183→CAN DPT>DBT>DBS>DBK→128267
STW
(Speed Through the Water)
CAN→0183 128259, 130577→VHW
0183→CAN VHW→128259
SOG
(Speed Over the Ground)
CAN→0183 128259, 130577→VTG, RMC
0183→CAN VTG>RMC>RMA→128259
Wind speed and angle
(Apparent)*1
CAN→0183 130306→MWV(A)
0183→CAN MWV(A)>VWR→130306
Wind speed and angle
(True)*1
CAN→0183 130306→MWV(T)
0183→CAN MWV(T)>VWT→130306
Heading (True)*2 CAN→0183 127250, 130577→HDT, VHW(T)
0183→CAN3 HDT>PFEC,Gpatt>VHW(T)→127250
Heading (Magnetic)*2 CAN→0183 127250, 130577→HDG, VHW(M)
0183→CAN HDG>HDM>VHW(M)→127250
Variation CAN→0183 127250, 127258→HDG, RMC
0183→CAN HDG→127250
Deviation CAN→
0183 127250→HDG
0183→CAN HDG→127250
Data Port Sentence, PGN (Title)