Operator's Manual

12
4. MAINTENANCE, TROUBLE-
SHOOTING
This chapter provides the information for keeping your unit in good working order.
4.1 Preventive Maintenance
Regular maintenance is important for good performance. Following the procedures in the table be-
low will help maintain performance.
Preventive maintenance
4.2 Fuse Replacement
Two 1A fuses are contained in the fuse holder in the power cable MJ-A10SPF0017-xxx, which is
used when supplying power to the SC-30 directly from the power source. If heading data is not
being output, first check the SC-30's breaker at the power source and the check if a fuse in the
power cable has blown. If it has blown, find out the cause before replacing the fuse. If it blows
again after replacement, request service.
Item Check point Remedy
Cabling Visually check cabling for
signs of wear and damage.
Check that connector is firm-
ly fastened.
Replace damaged cables.
Reconnect cable if it has loosened.
Cover Cleanliness of cover Dust can be removed with a soft cloth.
Do not use chemical based cleaners
to clean the cover, as they can re-
move paint and markings and deform
the cover.
Item Type Code No.
Fuse FGBO-A, 125A, 1A, PBF 000-157-847-10
NOTICE
Do not apply paint, anti-corrosive
sealant or contact spray to coating
or plastic parts of the equipment.
Those items contain organic solvents
that can damage coating and plastic
parts, especially plastic connectors.