User Manual

M
OUNTING THE
M
AGNET AND
S
ENSOR
54
between the sensor and magnet
can be made 1 to 2mm.
Tighten the sensor stay together
with the engine mounting flange.
(Temporary assembly)
Select the mounting method so
that the sensor does not touch
the frame, or other parts of the
helicopter. Temporarily mount
the sensor and select the magnet
mounting position.
Install the sensor to the sensor
stay using the accessory screws and washers.
Tighten the sensor stay together with the en-
gine using the engine mount screw.
Sensor adjustment
Adjust the sensor position to obtain a sen-
sor output of at least 60% in the “Revolution
sensor testing” menu within the “Governor
Basic Setting” section earlier in this manual.
1-2mm
Magnet
Sensor
2.2
mm
3.7mm 3.7mm
Center of sensor
is offset.
Sensor
case