AH 530-790 AH 530-720 Preface Safety notes 1. Important notes 1.1 For your safety 1.2 Operating for the first time 1.3 About use 2. Features 3. Operation 4. Cleaning and care 5. Maintenance 6. Assembly instructions 6.1 Technical data 6.
Preface With your new extractor hood, working in the kitchen will be even more fun. The appliance offers you a number of advantages: – A good extraction capacity with low noise values, – a large number of control functions, – optimum illumination of the cooking surface by a dimmable halogen light. To ensure that you will be able to use this appliance in all its diversity, read through the operating and assembly instructions conscientiously before operating it for the first time.
Safety notes Read And Save These Instructions. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b.) Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
1. Important notes 1.1 For your safety – Damaged appliances must not be operated. – The appliance must only be connected by an authorised specialist, paying attention to the relevant regulations of the power supply companies and the regional construction regulations. Also observe the assembly instructions! – Connecting cables must not come into contact with hot cooking surfaces. – Do not operate the extractor hood without inserted lamps. – Never operate the appliance without a grease filter.
1.2 Operating for the first time 1.3 About use Before operating the appliance for the first time, please pay attention to the following notes: – The appliance is intended solely for use in the household and must not be put to any other uses. – The appliance must be installed and connected by a specialist before it is operated for the first time. – In the event of malfunctions, first of all check the household fuses.
2. Features 1 Outgoing air duct 2 Control panel 3 Grease filter 4 Lighting 1 2 3 4 Fig. 2 Installation accessories: Grease filter saturation display Lighting Run-on Extraction level intensive Extraction level 3 Extraction level 2 Extraction level 1 Motor off Fig. 3 6 Stainless steel-design ventilation duct: LK 530-010 for ceiling heights of 7 ´ 3 ´ ´ - 8 ´ 6 ´ ´ / 2.20 - 2.66 m LK 530-020 for ceiling heights of 8 ´ 6 ´ ´ - 10 ´ 1 ´ ´ / 2.66 - 3.
3. Operation The AH 530-790 is 35 3/8 ´ ´ / 90 cm wide, and the AH 530-720 is 47 3/16 ´ ´ / 120 cm wide. Operation of both extractor hoods is identical. After they have been pressed, all functions selection keys except 0 (“Motor off”) are backlit in green. Light The lighting can be switched on or off, regardless of whether the wall extractor is in operation, by pressing the key (see Fig. 4). When you briefly press the key, the lighting is increased up to the maximum level.
The Int key for the intensive level should be pressed when browning and frying in an open pan (see Fig. 6). If you have switched on the hood by selecting the intensive level, it will be switched off again automatically after 5 minutes. Fig. 6 If you press the Int key while the hood is running at fan level 1, 2 or 3, the electronic control will switch back automatically to the previously selected fan level after 5 minutes (see Fig. 7). Fig.
Special functions: or Intensive time: You can set the intensive level running time to 3, 5 or 10 minutes by simultaneously pressing the Int key and the 1, 2 or 3 key and you can store this setting (see Fig. 9). When delivered, the appliance is set to five minutes, i.e. the combination of the Int key and the key 2. or Fig. 9 Delayed shut-off: Delayed shut-off is possible at any level. First press the required key 1, 2, 3 or Int and then press the key (see Fig. 10).
4. Cleaning and care Cleaning the grease filters The grease filter saturation display F flashes after an operating time of 30 hours to indicate that you should clean the grease filter (see Fig. 3). The grease filter can of course be cleaned at any time, even if the grease filter saturation display should not start to flash. The stainless steel grease filters can be removed easily for cleaning (see Fig. 13): Grip the grease filter handle and push the slide towards the rear.
Cleaning the extractor hood Clean the extractor hood and the aluminiumdesign ventilation ducts (LK 530-011/021) with a soft cloth and mild detergent solution only. Clean the stainless-steel design ventilation ducts (LK 530-010/020) with mild detergent solution and apply stainless steel care agent to the metal surface using a soft cloth. Cleaning the glass plates Fig. 15 Apply commercially available window cleaning agent with a soft, moist cloth.
5. Maintenance The appliance must be disconnected from the power supply during all repair work. If the appliance does not function correctly, check the fuses first. If the power supply is functioning correctly, but your appliance still does not work, please contact your Gaggenau dealer who will provide you with the address and telephone number of your nearest manufacturer’s authorized service agent or contact Gaggenau USA on (800) 828-9165. Specify the appliance type (see rating plate).
6. Assembly instructions 6.1 Technical data AH 530-790: Weight: 23.5 kg Dimensions: 35 3/8 ´ ´ x 20 10/16 ´ ´ 898 x 550 mm AH 530-720: Weight: 27.5 kg Dimensions: 47 3/16 ´ ´ x 20 10/16 ´ ´ 1198 x 550 mm Electrical connection Pay attention to the rating plate data. The appliance must only be connected by an authorised specialist. The specialist is responsible for perfect functioning of the appliance at its installation location.
6.2 Installation WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: The applicable regulations of the energy supply companies and the regional construction regulations must be observed when installing the hood. a.) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
As standard, the blow-out opening of the wall hood is in the upward direction. To pass exhaust air through the outer wall, we recommend the use of our telescopic wall box TM 150-045 (Ø 6 ´ ´ / 150 mm). Note: To prevent the ingress of water, e.g. condensate or rain water from an uncovered exhaust air shaft, our condensate separator RV 060-150 must be installed in the exhaust air line. The condensate separator must still be acciessible after installation.
Important: Before marking the securing holes, make sure that no electricity or water lines or other lines are laid at the drilling points in the wall. 15 (19/32") 300 (11 13/16") 310 (12 3/16") 230 (9 1/16") 76,5 (3") 396 (15 9/16") 270 (10 5/8") 62(2 7/16") min. 600 (24”) electric min. 700 (271/2”) gas Fig. 19 782/1082 (35 3/8" - 47 3/16") Proceed as follows: – From the bottom edge of the hood, mark a center line on the wall.
– Secure the hood on the wall with the four screws b (Fig. 21). – Establish the pipe connection. – Establish the electrical connection. – Stainless steel chimney only (LK 530-010/020): Pull the protective film off the chimney’s trims. Note: Avoid damaging the sensitive metal surfaces. – Fit the top of the chimney into the base. Make sure that the fastening holes on the side are at the top. – Put both chimney parts onto the hood.
Operating and assembly instructions AH 530-790 AH 530-720 Extractor hood