Operation Manual

24
ã=Warning
If the appliance is not in a cavity and a side panel is
accessible, the door hinge area must be covered at
the side for reasons of safety (risk of injury). The
covers are available as optional accessories from
customer service or specialist outlets.
Delivery
Your dishwasher has been checked thoroughly in the
factory to ensure that it is in working order. This may
cause small water stains. These will disappear after
the first wash cycle.
Technical specifications
Weight:
max. 60 kg
Voltage:
220–240 V, 50 Hz or 60 Hz
Connected load:
2.0–2.4 kW
Fuse:
10/16 A
Water pressure:
at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar).
At a higher water pressure: connect pressure-
reducing valve ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature 60 °C.
Installation
The required installation dimensions can be found in
the installation instructions. Level the appliance with
the aid of the height-adjustable feet. Ensure that the
appliance is situated securely on the floor.
A built-under or integrated appliance which is
installed subsequently as a free-standing
appliance must be secured to prevent it from
overturning, e.g. by screwing it to the wall or by
installing it under a continuous worktop which is
screwed to adjacent cupboards.
The appliance can easily be installed in a fitted
kitchen between wooden and plastic walls. If the
plug is not freely accessible, an allpole
disconnector with a contact opening of at least 3
mm must be fitted on the installation side to
satisfy the relevant safety instructions.
Waste-water connection
1 The required work sequence can be found in the
installation instructions. If required, fit a siphon
with an drainage connection.
2 Connect the waste-water hose to the drainage
connection of the siphon with the enclosed parts.
Ensure that the drainage hose is not kinked,
crushed or twisted and that there is no cover plate
in the drainage to prevent the waste water from
flowing out!
Fresh water connection
1 Connect the fresh-water connection to the tap
according to the installation instructions with the
enclosed parts.
Ensure that the fresh-water connection is not
kinked, crushed or twisted.
2 When replacing the appliance, always use a new
water supply hose.
Water pressure:
at least 0.05 MPa (0.5 bar), maximum 1 MPa (10 bar).
At a higher water pressure: connect pressure-
reducing valve ahead.
Inlet rate:
minimum 10 litres/minute
Water temperature:
cold water; hot water max. temperature 60 °C.