operation manual

GB
- 31 -
9. Troubleshooting guide
Problem Probable cause Corrective Action
Unit won’t start or
starts but will not
run.
- Incorrect starting procedures.
- Incorrect carburetor mixture adjust-
ment setting.
- Fouled spark plug.
- Fuel lter plugged.
- Follow instructions in the User Ma-
nual.
- Have carburetor adjusted by an Au-
thorized Service Center.
- Clean / gap or replace plug.
- Replace fuel lter.
Unit starts, but engi-
ne has low power.
- Incorrect lever position on choke.
- Dirty air lter.
- Incorrect carburetor mixture adjust-
ment setting.
- Move to RUN position.
- Remove, clean and reinstall lter.
- Have carburetor adjusted by an Au-
thorized Service Center.
Engine hesitates. - Incorrect carburetor mixture adjust-
ment setting.
- Have carburetor adjusted by an Au-
thorized Service Center.
No power under
load.
- Incorrectly gapped spark plug. - Clean / gap or replace plug.
Runs erratically. - Incorrect carburetor mixture adjust-
ment setting.
- Have carburetor adjusted by an Au-
thorized Service Center.
Smokes excessi-
vely.
- Incorrect fuel mixture. - Use properly mixed fuel (40:1 mix-
ture).
Poor performance
when operated
- Blunt chain
- Loose chain
- Sharpen or replace the chain
- Tension the chain
Engine dies - Empty petrol tank
- Fuel lter in the wrong position in
the tank
- Fill up the petrol tank
- Completely ll the petrol tank or or
re-position the fuel lter in the petrol
tank
Insu cient chain
lubrication
(the cutter rail and
chain get hot)
- Empty oil tank for the chain
- Oil lubrication openings moved
- Top up the oil tank for the chain
- Clean the oil lubrication hole in the
cutter bar (Fig. 2/Item A)
Clean the groove in the cutter bar
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers
accompanying products is permitted only with the express consent of the iSC GmbH.
Subject to technical changes
Anl_GMSE_1535_SPK7_Teil1.indb 31Anl_GMSE_1535_SPK7_Teil1.indb 31 09.05.14 08:2909.05.14 08:29