Conventional Flue Instructions

16
1. Safety Precautions
1.1 For your own and other’s safety, you must install this
appliance according to local and national codes of practice.
Failure to install the appliance correctly could lead to
prosecution. Read these instructions before installing
and using this appliance.
1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
1.4 Keep all plastic bags away from young children.
1.5 Do not place any object on or near to the appliance and
allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT
IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF THE
MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF USE.
FOR DETAILS OF CHANGING BETWEEN GAS TYPES
REFER TO SERVICING, SECTION 16, REPLACING
PARTS.
Unpacking
1.6 Remove the appliance from its packaging, and check that it
is complete and undamaged.
1.7 The glass lid is stored on top of the appliance. Remove and
store in a safe place.
Put the loose ceramic parts to one side so that they are not
damaged during installation.
2. Upgrading the Appliance
2.1 The appliance is fitted with a control valve that can easily be
upgraded to battery powered remote control.
There are two versions of this control which can be obtained
through your local Gazco stockist.
There is no requirement for this upgrade to be carried out by
an approved Gas engineer. However Gazco recommend
that this task is undertaken by a suitably competent person.
2.2 This upgrade can be fitted before or after installation but if
side clearances are limited then it will be easier to upgrade
the appliance before installation. Full instructions are
included with the kit.
If the appliance is left unattended for long periods of
time (e.g. vacation), it is recommended to place the
control valve in the Off or Pilot position.
Take care when leaving the appliance unattended,
in exceptional circumstances sound waves from
sources other than the transmitter can cause
changes in the ame height adjustment.
DO NOT install two or more appliances using
upgradeable controls in the same room, interference
between the remote control frequencies can occur.
Standard Remote Control
(PART NUMBER 8455)
2.3 This remote control can control the gas appliance after
the pilot has been lit. It can turn the main burner on and
regulate it from low through to high and back again.
It can turn the main burner off leaving the pilot burning.
Thermostatic and Timer Remote Control
(PART NUMBER 8456)
2.4 This remote control can control the gas appliance after the
pilot has been lit.
MANUAL MODE
Can be used to turn the main burner on and manually
regulate it from low through to high and back again. It can
also be used to turn the main burner off leaving the pilot
burning.
AUTO MODE
Will automatically regulate the room to a pre-set
temperature.
TIMER MODE
Will turn the appliance on and off according to a pre-set
programme and automatically regulate the room
temperature during the two on periods.
Installation Instructions