Conventional Flue Instructions

24
Small
Locate the tab on the glass plinth under the glass front and
insert the hooks into the slots on the front of the appliance,
see Diagram 35.
Midi & Medium
Insert the hooks into the slots on the front of the appliance,
see Diagram 35.
35
Midi & MediumSmall
10. Operating the Appliance
The control valve is located behind the glass plinth.
10.1 Remove the glass plinth to access the controls:
Small
Lift the hooks clear of the slots on the front of the appliance
and lower so that the tab on the glass plinth clears the glass
front, see Diagram 36.
Midi & Medium
Lift the hooks clear of the slots on the front of the appliance,
see Diagram 36.
36
Midi & MediumSmall
Installation Instructions
The valve has two controls, see Diagram 37.
1. The right-hand knob controls the pilot ignition.
2. The left-hand knob controls the main burner.
37
10.2 Refer to separate instructions if your appliance is upgraded
to include battery remote control. The instructions below
apply whether or not you have the remote upgrade.
Lighting the Pilot
10.3 To start the left-hand and right-hand control knobs must
both point to off (
):
10.4 Press in the right-hand control knob and rotate anti-
clockwise until a click is heard. Continue to press in. The
knob points to the pilot (
).
The pilot is lit.
10.5 Keep the knob depressed for 10 seconds before releasing.
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period
10.6 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
10.7 Turn the right-hand knob to the left to main burner
setting (
).
Adjusting the Flame height
10.8 You can now adjust the flame height and temperature using
the left-hand control knob.
10.9 Turn the left-hand knob anti-clockwise to increase the
flame height.
10.10 Turn clockwise to decrease the height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.