Conventional Flue Instructions

6
Small
Lift the hooks clear of the slots on the front of the appliance
and lower so that the tab on the glass plinth clears the glass
front, see Diagram 3.
Midi & Medium
Lift the hooks clear of the slots on the front of the appliance,
see Diagram 3.
3
Midi & MediumSmall
All Models
5.3 Remove the glass front to gain complete access to the
control valve and the viewing aperture by lifting the hooks
clear of the slots on the front of the appliance, see
Diagram 4.
4
5.4 Small and Midi only:
Using screwdriver remove the 6 screws securing the window
panel to the appliance, see Diagram 5, Arrows A.
Take care to support the glass when removing the screws.
5.5 Medium only:
Using screwdriver remove the 8 screws, securing the
window panel to the appliance, see Diagram 5, Arrows
A & B.
Take care to support the glass when removing the screws.
5
A
A
A
A
A
A
B
B
5.6 The glass frame must be refitted to the appliance following
cleaning or servicing. Hold in position and secure with the
screws.
5.7 Replace ALL of the securing screws ensuring that a screw is
present in all fixing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE GLASS
FRAME RETAINING SCREWS ARE LOOSE OR
MISSING.
User Instructions