Install Guide
11
Installation Preparation
Preparation WITH an Accessory Storage Drawer
• PSB9120 and PWB7030 are the only approved models to be installed under 36-3/4” height with a
storage drawer. CSB9120, ZSC1201, ZSC1202 and CWB7030 are not approved.
• As needed, see the Standard Mount Installation Preparation OR Flush Mount Installation Preparation
for configuration details. Note the modified cutout height below.
• Model ZSC1202 cannot be installed with an accessory storage drawer. See installation preparation
without an accessory storage drawer for this model.
STANDARD MOUNT
30Ǝ
23-1/2Ǝ
25-1/4Ǝ
Min.
21Ǝ
36-3/4Ǝ
Min.
Construct
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
FLUSH MOUNT (Monogram only)
23-1/2Ǝ
K*
22-5/8Ǝ
36-3/4Ǝ
Min.
Construct
solid bottom - Min.
3/8” plywood
supported
on all four sides.
Must be able to
support weight
of oven and
contents.
PREPARE THE OPENING (cont.)
The Advantium/Convection 120V can be installed in combination with other GE Appliances/Monogram
appliances. Always follow each product’s Installation Instructions to complete the installation.
Single Advantium/Convection 120V Installation:
Order a 30Ǝ wide single oven cabinet or cut the opening in a wall to the dimensions shown.
• Allow 2-1/8Ǝ case trim overlap on the sides, 1-1/16Ǝ overlap on the top and 7/8Ǝ overlap on the bottom of
the opening for all models.
• Oven overlaps will conceal cut edges on all sides of the opening.
• When installed over a single oven or a warming drawer, allow at least 2Ǝ between the two openings.
This separation will provide clearance for bottom overlap of the Advantium/Convection 120V and the
other appliance overlaps.
• The support must be level and rigidly mounted, flush with the bottom edge of the cutout.
Dimension 1/8”
Reveal
1/4”
Reveal
K 30” 30-1/4”
*See table for desired reveals on sides.