INSTALL JUNCTION BOX
The conduit is located at the top right on the back of
the oven.
Locate and install the junction box within reach of
the oven conduit.
Through the left or right sides of the cabinet
wall and into adjacent cabinet.
Or, through the cutout floor.
Or, in the upper cabinet.
ADVERTENCIA
El encendido eléctrico al circuito paralelo deberá estar
apagado mientras se realizan las conexiones de línea.
Use conductores de cobre únicamente.
Este electrodoméstico requiere que se realice una
conexión a tierra. El extremo libre del cable verde (cable
a tierra) debe estar conectado a una conexión a tierra
adecuada. Este cable debe permanecer conectado a la
conexión a tierra del horno.
Si la tubería de agua fría presenta interrupciones
por plásticos, juntas, conexiones de uniones u otros
materiales aislantes, NO use la misma como conexión a
tierra.
NO se debe conectar a tierra en una tubería de
suministro de gas.
REQUISITOS ELÉCTRICOS (Cont)
NO posee un fusible en el circuito neutro o de conexión
a tierra. Un fusible en el circuito neutro o de conexión a
tierra podría ocasionar una descarga eléctrica.
Consulte a un electricista calificado o personal del
servicio si tiene dudas de que el electrodoméstico se
encuentre conectado a tierra apropiadamente.
Si no se siguen estas instrucciones, se podrán
producir lesiones graves o la muerte.
Cutout
Height
ELECTRICAL REQUIREMENTS
Single Speedcook Installation
Product rating is 120/208 or 120/240 volt, 60 Hz,
30 amps. This product must be connected to a
supply circuit of the proper voltage and frequency
and protected by a time delay fuse or circuit
breaker. Power should be supplied from a separate,
dedicated 30-ampere branch circuit. Wire size
must conform to the requirements of the National
Electrical Code or the prevailing local code.
Combined Speedcook and Wall Oven
Installation
When installed in combination with a single wall
oven, use separate electrical junction boxes.
Refer to single oven installation instructions for
electrical requirements of that product.
These connections must be made by a qualified
electrician. All electrical connections must meet
National Electrical Code or prevailing local codes.
Combined Speedcook and Warming Drawer
Installation
When installing the Speedcook oven over an
electric warming drawer, a separate 120V, 60Hz,
properly grounded receptacle must be installed. See
instructions packed with the warming drawer.
WARNING
The electrical power to the oven branch circuit
must be shut off while line connections are being
made.
Use copper wiring only.
Electrical ground is required on this appliance.
The free end of the green wire (ground wire)
must be connected to a suitable ground.
This wire must remain grounded to the oven.
If cold water pipe is interrupted by plastic,
non-metallic gaskets, union connections or other
insulating materials, DO NOT use for grounding.
DO NOT ground to a gas pipe.
DO NOT have a fuse in the NEUTRAL or
GROUNDING circuit. A fuse in the NEUTRAL
or GROUNDING circuit could result in an
electrical shock.
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
Failure to follow these instructions could result in