PSB9240DF PSB9240SF PSB9240BL PSB9240EF ZSC2200 ZSC2201 ZSC2202

6
Installation Preparation
Preparation WITHOUT an Accessory Storage Drawer
PREPARE THE OPENING (CONT.)
Installation over a Warming Drawer:
NOTE: Additional clearances between the cutouts
may be required. Check to be sure the oven
supports above the Warming Drawer location do
not obstruct the required interior depth and height.
See Warming Drawer installation instructions for
details.
30”
23-1/2”
25-1/4”
17-1/2”
36-3/4”
Min.
2” Min.
(3”
recommended)
Per warming
drawer
requirement
Construct
Solid Bottom
Min. 3/8”
Plywood
Supported
by 2x4 or 2x2
Runners all
Four Sides
PREPARE THE OPENING
The Advantium 240V can be installed in
combination with other Built-In appliances.
Always follow each product’s Installation
Instructions to complete the installation.
Single Advantium 240V Installation:
Order a 30” wide single oven cabinet or cut the
opening in a wall to the dimensions shown.
Always maintain 36-3/4” minimum height from
the floor to the cutout in any single or combined
installation.
Allow the following clearances around the
cutout on the front surface of the cabinet: 5/8”
from the top, 2-3/8” from the side edges, and
í´IURPWKHERWWRP1RWHWKHVHUHIHUWR
minimum clearances required for installation
and do not reflect actual product dimensions.)
Oven overlaps will conceal cut edges on all
sides of the opening.
When installed over a single oven or a warming
drawer, allow at least 2” between the two
openings. This separation will provide clearance
for bottom overlap of the Advantium 240V and
the other appliance overlaps.
Construct a solid oven floor of 3/8” min. thick
plywood supported by 2 x 4 or 2 x 2 runners on all
sides.
The support must be level and rigidly mounted,
flush with the bottom edge of the cutout.
30”
23-1/2”
25-1/4”
17-1/2”
Construct
Base
Min. 3/8”
Plywood
Supported
by 2x4
or 2x2
Runners all
Four Sides
36-3/4”
Min.