User manual

K0214 Issue No. 5
4
CSA Certification
Markings:
Ex ia IIC T4, Class 1, Zone 0 and Class 1, Div.1
Groups A, B, C & D ..................................................... hazardous location designation
1999 LR110032-3 ....................................................... certificate reference
Amb Temp -10°C to +50°C ........................................ ambient temperature range
..................................... CSA monogram
DPI 705 IS .................................................................... specific apparatus type
Pressure range in mbar or psi ................................. full-scale pressure rating
Druck LTD, Groby, LE6 0FH, UK ............................... manufacturer's name and address
SN*******/YY-MM ...................................................... serial number and date of
manufacture, year-month
Requirements and Conditions
Batteries
WARNING: ONLY REPLACE BATTERIES IN A SAFE AREA
Power supply use only 3 x LR6 (AA) made by Eveready Energizer LR6, Varta 4006
or Duracell Procell MN1500.
Installation
WARNING:
D
O
NOT
USE
TOOLS
ON
THE
PRESSURE
INDICATOR
THAT
MIGHT
CAUSE
INCENDIVE
SPARKS
-
THIS CAN CAUSE AN EXPLOSION.
Installation should be carried out by qualified plant installation technicians in
compliance with the latest issue of Canadian Electrical Code (CEC).
Provide additional protection for indicators that may be damaged in service.
Maintenance
Note: The following applies to all instruments of the DPI 705 Series.
Return the instrument to the factory for any repairs, it cannot be repaired on-site.
To keep the DPI 705 accurate to 0.1% full-scale a calibration check should be
carried out once per year.
Cleaning
Clean the instrument case with a moist, lint-free cloth and weak detergent.