Instructions / Assembly

FINISHING THE FAN INSTALLATION
Fan Installation
ATTACHING THE FAN BLADES
L
K
FF
1.
Position the blade (L) over the blade holder (K) with the
threaded post upward direction as shown. Make sure
bottom edge of the blade (L) is fully seated against the
blade holder (K). With a phillips screwdriver, tighten the
blade screw (FF) to secure the blade to the blade holder (K).
2.
Remove and discard the preassembled plastic motor
blocks but retain the blade holder screws (EE). Secure the
blade holders (K) to the bottom of the motor assembly (E)
using the blade holder screws (EE).
K
EE
Plastic
motor block
E
12
Tighten all the 4 canopy mounting screws (O).
into place on the canopy (B).
10.
Align the slotted hole on the canopy trim ring (C) with
the mounting bracket push lever, Take both hands
and push the canopy trim ring (C) up to the top of the
canopy (B). The canopy trim ring (C) will snap and lock
O
B
C
Groove
Tab
8.
O
7.
Make sure the tab on the mounting bracket socket
is properly seated in the groove in the hanger ball/
downrod assembly. This will help to balance the
ceiling fan.
WARNING: Failure to properly seat the tab in the
groove could cause damage to wiring.
9.
Rotate the canopy to the right (clockwise), continue
turning the canopy until the screws (O) lock into
place on the receptacle j slots.
Note: You may need to loosen the canopy screws
slightly, if you find it's difficult to lock the screws