Specification

Listed by
Underwriters
Laboratories
GTD45EASJ
GE
®
Series 7.2 cu. ft. capacity Aluminized alloy drum electric dryer with HE Sensor Dry
Specification Created 7/15
For answers to your Monogram,
®
GE Profile
or GE
®
appliance questions, visit our
website at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
5.7 cu. ft. Dryers
2
Back View
Power
Cord Hole
30-1/2
5.8, 6.0 and 7.0 cu. ft. Dryers
5
Back View
Power
Cord Hole
4-1/2
Power Cord Locations
ELECTRIC DRYER RATING:
240V 5600W 24A 60Hz
208V 4400W 22A 60Hz
EXHAUST OPTION: 4-way rear, right, left and bottom
CIRCUIT REQUIREMENTS: An individual, properly-grounded
branch circuit, protected by a 30-amp circuit breaker or a time-delay
fuse, is required.
NOTE: Dryer wall outlet must be located within 36" of service cord
entry and acessible when dryer is mounted in position.
INSTALLATION INFORMATION: For complete information, see
installation instructions packed with your dryer.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a
minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
• The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the
National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DRYER EXHAUSTING INFORMATION : Use metal duct only, vertical and horizontal ducting.
22 1/2"
29 1/2"
27"
3 1/2"
1 3/4"
3 1/4"
8"
37 1/2"
42 1/2"
27"
5"
Power Cord 4 1/2"
11 3/4"
Side View
Rear View

Summary of content (3 pages)