MSDS

MATERIAL SAFETY DATA
SHEET
Version: 1.23
04/03/2012
M90044 12C
ELASTOMERIC SEALANT
Page 3/8
INHALATION
If inhaled, remove to fresh air. If not breathing give artificial respiration using a barrier device. If
breathing is difficult give oxygen. Get medical attention.
EYES
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
NOTE TO PHYSICIAN
None known.
5. FIRE-FIGHTING MEASURES
FLASH POINT
:
> 93.3 °C; 200 °F
METHOD
Estimated
IGNITION TEMPERATURE
:
Not applicable
FLAMMABLE LIMITS LEL
:
Not applicable
FLAMMABLE LIMITS UEL
:
Not applicable
SENSITIVITY TO MECHANICAL IMPACT:
No
SENSITIVITY TO STATI
C DISCHARGE
Sensitivity to static discharge is not expected.
EXTINGUISHING MEDIA
All standard extinguishing agents are suitable.
SPECIAL FIRE FIGHTIN
G PROCEDURES
Firefighters must wear NIOSH/MSHA approved positive pressure self-contained breathing
apparatus with full face mask and full protective clothing.
6. ACCIDENTAL RELEASE MEASURES
ACTION TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED
Wipe, scrape or soak up in an inert material and put in a container for disposal. Wash walking surfaces
with detergent and water to reduce slipping hazard. Wear proper protective equipment as specified in
the protective equipment section.