Specification

For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
PEP7036DT
GE Profile
36" Built-In Touch-Control Electric Cooktop
ADA
COMPLIANT
Listed by
Underwriters
Laboratories
Specification Revised 10/22
To insure accuracy, it is best to make a
template when cutting the opening in the counter
Cooktop
36-1/8"
20-7/16"
18-7/8"
33-3/4"
19-1/8" to
19-1/4"
33-7/8"
to 34"
2-1/2" MIN.
Required
1-3/4" MIN.
to rear wall
3-9/19" at front of unit and
5-9/16" at conduit location
13" MAX. depth of unprotected
overhead cabinets
30" MIN. Clearance from
countertop to unprotected
overhead surface
2" MIN. Clearance
from cutout to
nearest vertical
wall or cabinet on
left side of the unit
below the 15" MIN.
clearance height.
1 1/2" MIN. (30") and
2" MIN. (36") Clearance
from cutout to nearest
vertical wall or cabinet
on right side of the unit
below the 15" MIN.
clearance height.
36" MIN. for
36" cooktop
15" MIN. height
from countertop
to nearest cabinet
(including light rails)
on both sides of
cooktop
IMPORTANT: Requires a 5" free area between
the bottom of the cooktop to any combustible
material, i.e., shelving. Free area not required
when installing wall oven underneath cooktop.
Refer to installation instructions. Requires a 15"
minimum from cooktop to adjacent overhead
cabinets. Units are furnished with a 48" flexible
armored cable.
NOTE: 36" Ribbon cooktops are approved for
use over select GE 30" Single Wall Ovens and
Warming Drawers. Refer to cooktop and wall
oven/warming drawer installation instructions
packed with product for current dimensional
data. If installed with a GE Telescopic
Downdraft System, consult both the cooktop
and downdraft installation instructions packed
with product before installing. Cooktop gas/
electric supply may need to be re-routed
to install downdraft. The countertop cutout
requires 23-1/2" minimum flat countertop
surface and 25" minimum total countertop
depth. In addition, other clearances to front
edge of the countertop must be considered.
Before installing, consult installation
instructions packed with product for
current dimensional data.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
APPROXIMATE COOKING DIMENSIONS
VOLTAGE (60HZ AC) 240V 208V
CONNECTED LOAD (MAX.) 9.7kW 7.3kW
CURRENT DRAW (MAX.) 40.4 Amps 35.1 Amps
RECOMMENDED CIRCUIT BREAKER
50 Amps 40 Amps
NOTE: Check local codes for required breaker size.
2-1/2" MIN
From front edge
of countertop to front
edge of cooktop cutout
31-1/4" MIN
From top surface
of countertop to
top surface of
wall oven support
platform
INSTALLATION ABOVE A WALL OVEN
INSTALLATION ABOVE A WALL OVEN