Number Default Function Name Function Description
63 BAT VOLT LO WARN Battery Voltage has gone below maximum warning limit
64 AVG CURR HI ALRM Average Current has gone above maximum alarm limit
65 AVG CURR LO ALRM Average Current has gone below minimum alarm limit
66 AVG CURR HI WARN Average Current has gone above maximum warning limit
67 AVG CURR LO WARN Average Current has gone below maximum warning limit
68 AVG VOLT HI ALRM Average Voltage has gone above maximum alarm limit
69 AVG VOLT LO ALRM Average Voltage has gone below minimum alarm limit
70 AVG VOLT HI WARN Average Voltage has gone above maximum warning limit
71 AVG VOLT LO WARN Average Voltage has gone below maximum warning limit
72 TOT PWR HI ALARM Total Real Power has gone above maximum alarm limit
73 TOT PWR LO ALARM Total Real Power has gone below minimum alarm limit
74 TOT PWR HI WARN Total Real Power has gone above maximum warning limit
75 TOT PWR LO WARN Total Real Power has gone below maximum warning limit
76 GEN FREQ HI ALRM Generator Frequency has gone above maximum alarm limit
77 GEN FREQ LO ALRM Generator Frequency has gone below minimum alarm limit
78 GEN FREQ HI WARN Generator Frequency has gone above maximum warning limit
79 GEN FREQ LO WARN Generator Frequency has gone below maximum warning limit
80 GEN FREQ FAULT Generator Frequency exceeds nominal limits for valid sensor reading
81 ENG RPM HI ALARM Engine RPM has gone above maximum alarm limit
82 ENG RPM LO ALARM Engine RPM has gone below minimum alarm limit
83 ENG RPM HI WARN Engine RPM has gone above maximum warning limit
84 ENG RPM LO WARN Engine RPM has gone below maximum warning limit
85 ENG RPM FAULT Engine RPM exceeds nominal limits for valid sensor reading
86 SWITCH IN AUTO Key Switch in AUTO digital input active
87 SWITCH IN MANUAL Key Switch in MANUAL digital input active
88 E-STOP ACTIVE Emergency Stop Status digital input active
89 REMOTE START ACT Remote Start digital input active
90 DIG INPUT 05 ACT DI-1, Digital Input #5 active
BATT CHARGE FAIL Battery Charger Fail digital input active
91 DIG INPUT 06 ACT DI-2, Digital Input #6 active
RUPTURED BASIN Ruptured Basin digital input active,
PROP LEAK ACT Propane Gas Leak digital input active,
LOW FUEL PRS ACT Low Fuel Pressure digital input active
92 DIG INPUT 07 ACT DI-3, Digital Input #7 active
LINE POWER ACT Line Power digital input active
93 DIG INPUT 08 ACT DI-4, Digital Input #8 active
GEN POWER ACT Generator Power digital input active
94 DIG INPUT 09 ACT Digital Input #9 active
MODEM DCD ACT Modem Carrier Detect digital input active
95 MODEM ENAB ACT Modem Enable digital input active
96 ILC ALR/WRN #1 ILC controlled: ILC warning or alarm signal # 1
97 ILC ALR/WRN #2 ILC controlled: ILC warning or alarm signal # 2
98 IN WARM UP Generator is running, but not fully warmed up yet
99 IN COOL DOWN Generator is running, but cooling down before shutting off.
100 CRANKING Generator is starting – the starter is engaged
101 NEED SERVICE Maintenance item has expired
102 SHUTDOWN GENSET Shutdown alarm is active