Manual

*GarageDoorOpener........................... 500to750
HairDryer........................................ 1200
HandDrill................................... 250to11O0
HedgeTrimmer..................................... 450
ImpactWrench..................................... 500
Iron............................................. 1200
*JetPump......................................... 800
LawnMower...................................... 1200
LightBulb......................................... 1O0
MicrowaveOven............................. 700to1000
*MilkCooler...................................... 1100
OilBurneronFurnace................................. 300
OilFiredSpaceHeater(140,000Btu)..................... 400
OilFiredSpaceHeater(85,000Btu)...................... 225
OilFiredSpaceHeater(30,000Btu)...................... 150
*PaintSprayer,Airless(1/3HP)......................... 600
PaintSprayer,Airless(handheld)........................ 150
Radio........................................ 50to200
*Refrigerator....................................... 700
SlowCooker....................................... 200
*SubmersiblePump(1-1/2HP)........................ 2800
*SubmersiblePump(1HP)........................... 2000
*SubmersiblePump(1/2HP).......................... 1500
*SumpPump................................ 800to1050
*Allowthree(3)timesthelistedrunningwattsforstartingthesesdevices.
NOTE:
When an electricmotoris started,the "OVERLOAD"LEDmay
lightup for up t0 five (5) seconds(thisis n0rmal), if itstayson,
a fault has0ccured. Removeall loadsand shutdown generator
to resetthe alarm. Restart the generator. If the "OVERLOAD"
LEDremainslit, contacta GeneracDealerfor assistance.
USINGTHEFLEXPOWERTM SWITCH
When the accessories connected to the generator are going to
be used intermittently (such as a hand drill), the FtexPowerTM
switch can be pushedto the "ON" (I) position. Thiswill lower the
generatorenginespeed when loads are not being applied,saving
fuel, reducingenginewear and extendingruntime.
USINGTHE12VDCBATTERYCHARGER
The 12 VDC receptacle may be used to recharge 12 VDC
automotivebatteriesonly.TheDCchargingoutput is not regulated.
The circuit protector does not preventover-charginga battery.
1. Connect the charging cable to the generatorfirst, then the
battery,ALWAYSconnectingthe red leadto positive (+) and
the blackto negative(-).
Do not permit smoking, open flame, sparks
or any other source of heat around a battery.
Wear protective goggles, rubber apron
and rubber gloves when working around
a battery. Battery electrolyte fluid is an
extremely corrosive sulfuric acid solution
that can cause severe burns. If a spill occurs,
flush area with clear water immediately.
Storage batteries give off explosive hydrogen
gas white recharging. An explosive mixture
wiii remain around the battery for a long
time after it has been charged. The slightest
spark can ignite the hydrogen and cause an
explosion. Such an explosion can shatter the
battery and cause blindness or other serious
injury.
,_ NEVER reverse the polarity when connecting
the battery terminals to the charging jack.
Severe damage may occur to the generator
and battery.
2. Keepthe FlexPowerTM switch in the "OFF"(O) position.
3. Start the generatorand use it as normal. Chargingtime will
vary with batterysize andcondition. Checkthe voltageat the
batteryterminals oncethe charging cablehas beenunplugged
or the generatorhas beenshut down.
NOTE:
Thisreceptaclecannot recharge5-V01tbatteries and cannot
be used to crankan engine having a discharged battery.
SHUTTINGDOWN
Oncethe generatoris no longerneededit can be shut down.
1. Switch off any accessoriesconnectedto the generator.Unplug
any cords to the 120 VAC duplexoutlets or the 12 VDCplug.
2. Turn the fuel valve to the "OFF" (0) position (Figure 7). A
switch behind the fuel valve grounds the ignition system,
stoppingthe engineand the fuel supply is shut off.
3. Closethe vent on the fuel cap.
4. Allow the generatorto cool beforemoving or storing.
ACAUTION!
,_t Always allow the generator to cool off before
storing. High temperatures will be present
at the rear of the unit for some time after
shutdown.
Figure 7- Turn Off Fue/