GENERAC MODELS: 005796-0 (XG6500), 005797-0 (XG7000), 005798-0 (XG7OOOE), 005800-0 (XGSO00), 005747-0 (XGS000E) 0wnsr's XGSeries6,500-8, L M|TED WattPorta e Generator _
introduction .............................................................1 Read this iVlanualThoroughly .................................1 Maintenance.........................................................11 3.1 MaintenanceSchedule.................................................11 3.2 Product Specifications..................................................11 Safety Rules...........................................................1 StandardsIndex.......................................................
iNTRODUCTiON Thankyou for purchasingthis model by GeneracPowerSystems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical power to operate electrical loads where no utility power is available or in place of utility due to a power outage. BEADTHiSMANUALTHOROUGHLY If any portion of this manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures.
• Never usethegenerator oranyofitspartsasastep.Stepping ontheunitcanstressandbreakparts,andmayresultin dangerous operating conditions fromleaking exhaust gases, fuelleakage, oilleakage, etc. • Onelectric startmodels, disconnect thePOSITIVE (+) battery cablefromtheengine starterORtheNEGATIVE (-) battery cablefromthebatteryterminal, whichever is easier, before transporting thegenerator. NOTE: This generator is equipped with a spark arrestor muffler.
* Do not insert objects through unit's cooling slots. * Do not operate the generator if connected electrical devices overheat,if electricaloutput is lost, if engineor generatorsparks or if flames or smoke are observedwhile unit is running. MODELNO: SERIALNO: * Keepa fire extinguishernear the generatorat all times.
1.1 UNPACKING • Refer to Figure 2 and install the wheel kit and frame foot as follows: • Removeall packagingmaterial. • Removeseparateaccessory box. • Removecarton off the generator. 1.1.1 ACCESSORY BOX Checkall contents (Figure1). If any parts are missing or damaged locate an authorizeddealer at 1-888-775-6937.
2.1 KNOWTHE GENERATOR Figure 3 - GeneratorLocations Read the entire Owner's Manual and Safety Rules before operatingthis generator. 2 5 8 9 10 11 Compare the generator to Figures 3 through 6 to become familiarizedwith the locationsof various controls and adjustments. Savethis manualfor future reference. 1. Choke Knob- Usedwhen starting a cold engine (Pull/Push). 2. EngineSwitch - Controls the operation of the generator.On electric start models the switch is Start/Run/Stop.
2.1.1 BATTERYCONNECtiONfXG7OOOE & XG8OOOE) NOTE: The battery shippedwith the generator hasbeen fully charged. A battery may lose someof its chargewhen not in use for prolongedperiodsof time. If the battery is unable to crank the engine, plug in the 12V chargerincludedin the accessory box (see the Chargingthe Battery section).RUNNINGTHE GENERATOR DOESNOTCHARGETHE BATTERY. The positive battery wire was deliberately left detached for shipping.
2.4 HOW TO USETHEGENERATOR SpecialRequirements If there are any problems operatingthe generator,pleasecall the generatorhelplineat 1-888-436-3722. There may be Federalor State Occupational Safety and Health Administration(OSHA)regulations,local codes, or ordinancesthat apply to the intendeduse of the generator.
2.4.3 NEUTRAL70 FRAMEGROUNDING If service work is performed on the alternator, DO NOT discard the white jumper wires from the terminal block to the alternator ground, located on the rear bearing carrier. Always make sure the wires are properly connected before using the generatorafter alternatorservice work is done (Figure7).
Electric Nail Gun.................................... 1200 Electric Range(per element)........................... Electric Skillet...................................... *Freezer ............................................ 1500 1250 700 *Furnace Fan (3/5 HP) ................................ *Garage Door Opener............................ Hair Dryer......................................... Hand Drill .................................... HedgeTrimmer...................................... Impact Wrench....
Do not overfill the fuel tank. Alwaysleave roomfor fuel expansion,if the fuel tank is overfilled,fuel can overflow onto a hot engine and causeFiRE or EXPLOSION.Wipe up any spilledfuel immediately. Figure 10 - Fuel Shut-off Valve • Use regular UNLEADEDgasolinewith the generatorengine. Do not use premium gasoline. Do not mix oil with gasoline. • Do not use gasoline with more than 10% alcohol such as E85 or Methanol. i • Cleanarea around fuel fill cap, remove cap.
2.8.1 ELECTRICSTARtiNG(XG7OOOE & XGSOOOE) • Tostart the engine,press and hold the Start/Run/Stopswitch in the "Start" position. The enginewill crank and attempt to start. Whenthe enginestarts, releasethe switch to the run position. • When the engine starts, push choke knob to "1/2 Choke" position until the engine runs smoothly and then fully in to the "Run" position. If engine falters, pull choke knob back out to "1/2 Choke" position until the engine runs smoothly and then to "Run" position.
Model # ............................................................... 005797-0, 005798-0 RatedMax. Power................................................................... 7.0 kW** Surge Power............................................................................. 8.75 kW RatedAC Voltage...................................................................... 120/240 RatedMax AC Load Current @ 240V............................................................. 29.2 Amps** Current @ 120V...................
NOTE: DO NOTuse a garden hose to clean generator. Water can enter the engine fuel system and cause problems. In addition, if water enters the generatorthroughcoolingair slots,some water will be retained in voidsand crevices of the rotor and stator winding insulation.Water and dirt buildupon the generatorinternal windings will eventuallydecrease the insulationresistanceof these windings. • Coat gasket of new filter with clean engine oil.
3.6 GENERAL Figure 13- Air Filter The generatorshould be started at least once every seven days and be allowedto run at least 30 minutes. If this cannot be done and the unit must be stored for more than 30 days, use the following information as a guide to prepareit for storage. NEVER store engine with fuel in tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, spark or pilot light as on a furnace, water heater, clothes dryer or other gas appliance.
3.8 OTHER STORAGE TiPS Figure 16 - Battery Removal • Do not store gasolinefrom one seasonto another. 1_ • Replaceany gasolinecan that starts to rust. Rust and/or dirt in the gasoline will cause problems with the carburetor and fuel system. • If possible,store the unit indoors and cover it to give protection from dust and dirt. Cover the unit with a suitable protective cover that does not retainmoisture. ASSEMBLY if • BE SURE TO EMPTY THE FUEL TANK.
5.1 TBOUBLESHOOTING GUIDE Engineis running,but noAC output is available. 1. 2. 3. 4. 5. Circuit breakeris open. Poor connection or defective cord set. Connecteddevice is bad. Fault in generator. GFCItrips the 20 Amp outlet. 1. 2. 3. 4. 5. Reset circuit breaker. Check and repair. Connect another device that is in good condition. ContactAuthorizedService Facility. Repairthe "short" and reset the GFCI. 1. 2. 3. 4. Disconnect shorted electrical load. See"Don't Overloadthe Generator".
17
CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY YOUR WARRANTY RIGHTS AND OBLIGATIONS STATEMENT The California Air Resources Board (CARB) and the United States Environmental Protection Agency (EPA), together with Generac Power Systems, Inc. (Generac), are pleased to explain the Emission Control System warranty on your new 2008 and later generator.
EMiSSiON CONTROL Emission Control System Warranty (ECS warranty) for equipment SYSTEM WARRANTY using small spark-ignited engines: (a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter.
GENERAC POWER SYSTEMS "TWO YEAR" LiMiTED WARRANTY XG SERIES PORTABLE GENERATORS FOR For a period of two years from the date of original sale, Generac Power Systems, Inc. (Generac) warrants its XG Series generators will be free from defects in materials and workmanship for the items and period set forth below. Generac will, at its option, repair or replace any part which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Dealer, is found to be defective.
MODELO: 005796-0(×G6500), 005797-0(×GTO00), 005798-0 (XG7OOOE),005800-0 (×GSO00), 005747-0 (XG8OOOE) [] XGSeriesGeneradorportatilde6,500-8, OS
Introduccion ............................................................1 iVlantenimiento......................................................11 Leaestemanualcornpletamente ............................1 3.1 Cronogramade mantenimiento..................................... 11 3.2 Especificacionesdel producto...................................... 11 Reglasde seguddad...............................................1 indice deestandares ......................................................
INTRODUCCION Gracias por comprar este modelo de Generac Power Systems, Inc. Este modelo es un generadorimpulsado por motor, refrigerado por aire, compacto y de alto rendimiento disehado para proporcionar energia electrica para operar cargas electricas dondeno haya servicio publico de electricidado en reemplazode la red electrica en caso de apagones.
Guarde estas instrucciones - El fabricante sugiere que estas reglas para la operaciCn segura se copien y publiquen cerca del sitio de instalaciCn de la unidad. Debe insistirse en la seguridad para todos los operadores y potenciales operadores de este equipo En los modelos de arranque electrico, desconecte el cable de bateria POSlTIVO(+) del arrancador del motor 0 el cable de bateria NEGATIVO(-) del terminal de la bateria, Io que sea mD.sfD.cil,antes de transportar el generador.
* Limpie cualquier derrame decombustible inmediatamente. Asegurese dequenosehaya dejado materiales combustibles sobre ocerca del generador. Mantenga ela.rea circundante delgenerador limpia y libre deresiduos yconserve unespacio decinco (5)pies atodos loslados para permitir una ventilacion apropiada delgenerador. * Noopere el generador si losdispositivos electricos conectados sesobrecalientan, silasalida electrica sepierde, si elmotor o el generador echan chispas osiseobserva humo cuando launidad esta.
1.1 DESEMPAQUE NOTA: • Retiretodo el material de empaque. • Retirela caja separadade accesorios. • Retirela caja del generador. 1.1.1 CAJADE ACCESORiOS Revise todo el contenido (figura 1). Si alguna parte no se encuentra o esta,dafiada,ubique a un concesionarioautorizadoen el tell 1-888-7756937.
2.1 CONOCiENDOELGENERADOR 22. Arranque de culata - Usepara arrancarel motor manualmente. Lea compietamenteel manual delpropietarioy las regiasdeseguridad antes de operar este generador. Compareel generadorcon lasfiguras de la 3 a la 5 para familiarizarsecon las ubicaciones de los diversos controles y ajustes. Guardeeste manual para referenciasfuturas. 1. 2. 3. 4. 5. 6. 7. 8. Figura 3 - Controles del generador 1 Palanca de choke- Arrancar un motor frio (jalar/empujar).
2.1.1CONEXlON DELABATERiA NOTA: La bateria incluida en el generador ha sido cargada completamente. Una bateria puede perder algo de su carga cuando no se le usa por tiempo prolongado. Si la bateria es incapaz de arrancar el motor, conecte el cargador de 12 voltios incluido en la caja de accesorios (ver la seccion Cargando una bateria). EL HACER FUNClONAREL GENERADORNO CARGALA BATER/A. Este cable fue dejado deliberadamentedesconectadopara el embarque.
2.4 C6MOUSARESTE6ENERADOR ,_ ,_Los ,_EI Nunca opere en _reas cetradas o interiotes. NUNCA Io use en el hogar ni en _reas parcialmente encerradas come los garajes. Uselo SOLO en exteriores y lejos de ventanas abiertas, puertas, ductos de ventilaci6n yen _reas que no acumular_n el mortal gas del escape. humos del escape del motor contienen mon6xido de carbono. Este gas peligroso, si se aspira en concentraciones suficientes, puede hacerle perder la conciencia y causarle la muerte.
2.4.3 CONEX/ON A T/ERRADELNEUTROAL MARCOS 2.5 NO SOBRECARGUEELGENERADOR Si se esta dando servicio al alternador, NO descarte los cables del jumper blanco del bloque terminal a la tierra del alternador,ubicada en la portadora de cojinetes posterior.Siempre aseguresede que los cables esten conectados apropiadamenteantes de usar el generadorluego de que se hayadado servicio al generador.Veala figura 7.
Cortador desetos ....................................................................... 450 Herramienta deimpacto .............................................................. 500 Plancha .................................................................................... 1200 arrancar 8e ,_ Cuaiquierintent{)de el motor antes de que le baya dado servicio apropiado conel aceite recomendado puede * Eyector ....................................................................................
Figura9 - Tanquede combustible NOLLENAR ma,s atlade esta separacion 2.8.1 ARRANQUEMANUAL IMPORTANTE:Esimportante evitar que se formen depositosde goma en las partes del sistema de combustible como el carburador,la manguera de combustibleo eltanque durante el almacenamiento.Los combustibles mezclados con alcoholes (llamados gasohol, etanol o metanol) pueden atraer la humedad, Io que Ilega a la separacion y formacion de a_cidos durante el almacenamiento.
2.10SISTEMA DEAPAGADO P0RBAJAPRESION DEACEITE El motor esta equipado con un sensor de presionque apagael motor en forma automatica cuandola presion de aceitebaja a menos de 5 psi. Si el motor se apagay eltanque de combustible tienesuficiente gaolina, revise el nivel de aceite de motor. Unretardoincorporado al sistema de apagado por baja presion de aceite permite que la presion de aceite se acumule durante elarranque.
3.2.2 ESPEC/F/CAC/ONES BEL MOTOR 3.3 REC01VlENDACiONES GENERALES Potencia nominal en caballos @ 3600 RPM................................... 14.5 Desplazamiento............................................................................ 410cc Tipo de bujias ..................................... ChampionRC14YCo equivalente Espaciamientode la bujia............................. 0.030 pulgadas o 0.76 mm Capacidadde gasolina......................................... 8 galones americanos Tipo de aceite......
3.3.4 REV/SARELN/VELDE ACE/TE Figura 12 - Espaciamiento de la bujia Yea la seccion "ANTES DE ARRANCAREL GENERADOR"para mayor informacbn sobre la revision del nivel de aceite. El nivel de aceite debe revisarse antes de cada uso, o al menos cada ocho horas de operacion. Siempre mantengael nivel de aceite. 3.3.5 CAMBiODEACEITEYF/LTRO DEACEITE Cambie el aceite y el filtro luego de las primeras 30 horas de operacion. Cambieel aceitecada 100 horas o cadacambio de estacion luegode ello.
3.7 ALMACENAMIENT0 P0R LARGOPLAZ0 Si usa el generador sobre algun terreno cubierto de c_sped, arbustos o plantas, debe estar equipado con un supresor de chispa. El dueho o el operador deben mantener el supresor de chispa en buenas condiciones. Limpie e inspeccioneel supresor de chispa cuando elmotor se encuentre a temperatura ambiental, como sigue: • Retireel escudo de calor del silenciador retirandolos cuatrotornillos.
4.1 REEIVIPLAZ0 DE LA BATERJA (XG7000E & XGB000E) Para reempiazarla bateria (verfigura 16) • Retire el panel lateral como se muestra. Retirelos cuatro pemos que aseguraneltanque de combustible. • Gire la va.lvulade combustible sobre el panel de control a la posicbn "OFF". • Tire el tanque de combustible hacia atra.s ligeramente y retire la manguera de combustible que va del motor a la va.lvula de combustible.
5.1 GUJA DEDETECCI6N DEPROBLEMAS El motorestafuncionando, perono haysaiida deACdisponibie. 1. 2. 3. 4. 5. El interrupterde circuitoesta.abierto. Pobreconexiono cabledefectuoso. El dispositivoconectadoesta.mai. Fallaen elgenerador. GFCIaccionalatoma de 20 amp. • 1. 2. 3. 4. 5. Reinicieel interrupterde circuito. Revisey repare. Conecteotro dispositivoque esteen buenascondiciones. Contactea un servicio autorizado. Repareelcorto y reinicieel GFCI. 1. 2 3. 4. Desconectela cargaelectricaen corto.
17
DECLARACl6N DE GARANT{A DE CONTROL DE EMISIONES FEDERAL SUS DERECHOS Y OBMGACIONES DE GARANTiA Y DE CALiFORNiA El directorio de recursos de aire de California (CARB) y la Agencia de protecci6n ambiental de los Estados Unidos (EPA) junto con Generac Power Systems, Inc.
GARANTiA DEL SISTEMA Garantia de sistema de control de emisiones DE CONTROL DE EMISIONES (garantia ECS) para equipo que usa motores pequehos de chispa. (a) Aplicabilidad: Esta garantia se aplica a equipo que utiliza motores pequehos para fuera de pista. Et periodo de garantia ECS empezar& en la fecha en que el equipo nuevo es comprado por o entregado a su propietario/comprador final original y continuar& por los siguientes 24 meses consecutivos.
GARANTiA UMITADA DE "DOS ANOS" GENERADORES DE S|STEMAS PORTAT|LES DE POTENC|A SERIE XG GENERAC PARA Por un periodo de dos ahos desde la fecha de la venta original, Generac Power Systems, Inc. (Generac) garantiza sus generadores serie XG como libres de defectos en materiales y mano de obra por los items y periodos indicados abajo.