Operation Manual

Owner's Manual
6 - 17
Edit Sequencer
Sequencer
2V specifies the Key On velocity of the note in 1V with values 0... 127.
Perhaps you discover that you didn’t place enough emphasis one or two notes of
your recording. You can increase their respective Dynamic values to raise their
loudness.
If the sound of a track incorporates a dynamic switch, by modifying the dynamic
value you can switch from one sound level to the other.
3V specifies the Key Off velocity of the note in 1V with values 0... 127.
Some sounds have an incorporated sensitivity to variations in the Key Off
Envelope rate. Modifying this parameter affects this sound parameter only in cases
where the sound has a non-zero value for the Key off rate dynamic sensitivity
parameter.
GATE specifies the note length and takes the values 0... 65535.
The Gate parameter only applies to the notes.
In order to make it possible for a note to be held almost indefinitely WX has a very
high Gate time, equivalent to the possibility of holding down a note for approxi-
mately 85 bars (for a time signature of 4/4).
Considering that a quarter note has a sequencer resolution of 1/192, a whole note
consists of 192 x 4 = 768 units; 65535 ÷ 768 = 85,33 bars.
To move a note event:
1. Select the Bar pointer and rotate the Dial to move the event to any song position.
2. Select the Beat pointer and rotate the Dial to move an event within a bar.
3. Select the sequencer resolution and rotate the Dial to move an event from one beat
resolution to another.
When Status = Program change:
1V specifies the first number of a Program change with values 1... 128 (normal or
extended Bank Select format).
Modify this value to specify a new Program change. You will most probably have
to modify the 2V value if you are working with Bank Select numbers.
2V specifies the second number of a Program change with values 1... 128 - second
program change number of the Bank Select format.
You can emit any value up to 127 for the second Program change number,
particularly useful if the track also transmits to an external MIDI device capable
of receiving Bank Select data.
For example, the external device could contain a sound with Program Change
number 6-46, unlike the WX Generation which has a maximum capacity of 6-3 for
the standard value 6.
3V does not apply.
Downloaded from www.Manualslib.com manuals search engine