Use and Care Manual

MEASURING DC VOLTAGE
๎€๎€‚ Warning
Do not measure voltage higher than 600V. Doing
so may damage the meterโ€™s internal circuitry. If
the voltage is over 1000 VDC, the beeper will
sound continuously, indicating an over-range
measurement.
(1) Set the function switch to the position.
(2) Plug the black and red test leads into the
โ€“ and + input terminals, respectively.
(3) Touch the black test lead to the lower-
potential point of the circuit under test, and
the red test lead to the higher-potential point.
(4) Read the measured voltage on the display. If
the test leads are reversed, a minus sign will
appear to the left of the displayed value.
13
RED TEST LEAD
BLACK TEST LEAD
RED TEST LEAD
BLACK TEST LEAD