Installation & Assembly

®
5
7.1
Remove the thermostatic handle assembly from valve.
7.2-A
Recalibrating Output Temperature for High Temp Over-Ride Position.
The High Temp Over-Ride Position is pre-calibrated at the factory for approximately 100˚F. If you require a different
High Temp Over-Ride position, use the following procedure:
7.2-B
Checking Valve Maximum Output Temperature
Most municipalities require a maximum output temperature for point of use mixing valves. Depending on your local
codes and your input water temperatures and pressures, your maximum output temperature will vary accordingly.
Please check your maximum output temperature using the following procedure.
1) Turn off all volume controls.
2) Depress the High Temp Over-Ride Button and rotate the Thermostatic valve handle counter-clockwise until the handle
stops rotating. Do not force the handle beyond the factory installed Maximum Temp Stops.
3) Carefully turn on the volume control and allow water temperature stream to stabilize. USE EXTREME CAUTION, AS
MIXED WATER TEMPERATURE WILL MOST LIKELY CAUSE HOT WATER SCALDING.
4) If the output temperature is above the maximum allowed output temperature as prescribed by your local building
codes or if you want to limit the maximum hot water temperature to a temperature lower than prescribed by your
building codes, please see 7.2-C below.
1.) Remove the handle assembly (see 7.1)
2.) For higher temperature, rotate the cartridge stem counter-clockwise until the desired temperature is reached. For a
lower temperature rotate the cartridge stem clockwise until the desired temperature is reached.
3.) Reinstall the handle assembly(See 7.3)
© 2008 Danze, Inc. All rights reserved.