User's Manual

12 GS750
plus
Power Cords
1. Insert the female connector of the GS750
plus
plotter power
cord into the socket on the rear panel of the plotter.
2. Connect the power cords for both the GRAPHIX ADVANTAGE
system and the GS750
plus
to the multiple outlet strip included
with the GRAPHIX ADVANTAGE. The strip should be
plugged into a standard, grounded electrical outlet (115V +/-
10% AC, 60 Hz or 230V AC, 50 Hz).
3. Turn power on at the system and the plotter.
CAUTION: When the power is on, never try to manually move
the carriage, move the drum, rotate the tool, or force the tool
up or down. Attempting to manually move the GS750
plus
in
any axis of movement while the power is on may damage the
plotter.
Power-up Sequence
When the GS750
plus
is turned on, the following sequence occurs:
1. A short beep sounds, the Power light comes on, and the RUN
CONT, RUN SING and SWIVEL KNIFE lights blink.
2. As the GS750
plus
performs self-check tests, the lights over the
RUN and SWIVEL KNIFE keys flash, and an additional beep
sounds.
3. When the self-check is complete, the lights blink and a beep
sounds.
4. The plotter goes off-line in tangential knife mode. Only the
Power light remains on. This is the initial setting at power-up.
Note: Rapid, continuous beeping and flashing lights may signal a
self-check error. See the "Error Conditions" section for more
information.