User's Manual

Operation 41
RUN SINGLE KEY
Plot
Use RUN SINGLE to plot a single job. This plot mode allows the
operator to reposition material between jobs and/or to pen plot
using paper before cutting vinyl. RUN SINGLE may be used with
either swivel knife mode or tangential knife mode.
1. Press SWIVEL KNIFE to select a knife mode. (For swivel knife
mode, the light over the SWIVEL KNIFE key is on. For
tangential knife mode, the light is off. Press SWIVEL KNIFE
to select the knife mode desired.)
2. Press RUN SINGLE. The light over the RUN SINGLE key
comes on and the GS750
plus
plots a single job. If other plot
files are received from the GRAPHIX ADVANTAGE while the
first job plots, then a waiting list, or
queue
, of these jobs is
created.
The GS750
plus
returns to the off-line status after the job plots. It
remains in the knife mode selected.
The GS750
plus
waits for the operator to press the RUN SINGLE
key again to plot the next job. If other jobs are lined up in the
queue, the green lights above the two RUN keys will flash.
Controlled Stop
Use RUN SINGLE (or RUN CONT) to pause plotting and check
the current job.
1. Press the currently selected RUN key during a job to pause
the job. The GS750
plus
stops the job at the next logical break
in the program.
Note: Do not use slew key or orientation for the current job
will be lost.
2. Press either RUN key to resume plotting at the exact same
point.
RUN
SINGLE