DTP1 GATE OPENER INSTALLATION AND OWNERS MANUAL A 12V BATTERY IS REQUIRED TO OPERATE OPENER AND IS INCLUDED! *If using solar you will need to add another 12V Battery to your Battery Box Kit. WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.
CONTACT US: 1572 Capital Circle NW, Tallahassee, FL 32303 ghostcontrols.com For sales, product information, or to locate a retailer near you: Call: 850-558-5520 Monday through Friday: 8:00–5:00 EST For installation assistance and technical support: Call: 850-898-1411 Monday through Friday: 8:00–5:30 EST Product information, technical article, and installation videos can be found at: myghostcontrols.force.com/Support/s or Ghostcontrols.
CONTENTS 3 CONTENTS Installation and Owners Manual Warranty Registration Operator Specifications System Safety System Overview Installation Planning Tools Needed Included Parts PULL-TO-OPEN INSTALLATION Control Box Installation Battery Installation Connecting Arm to Control Box Setup System Controller Front Mount Gate Bracket Installation Setting the Closed Limit Powering the System AC Powering the System Solar Setting the Auto Close Feature PUSH-TO-OPEN INSTALLATION Co
DTP1 SINGLE KIT BEFORE YOU BEGIN: ■ A Ghost Controls ABBT Battery Box Kit is required to power the operator and is included with one 12v battery, if your using solar you will need to add another 12v battery to that box. ■ Push-To-Open applications (gate that swings away from the property) will require the Ghost Controls push-to-open bracket kit (AXPO).
DTP1 SINGLE KIT 5 PROTECT YOUR INVESTMENT! Get An Additional 6 Months Warranty when you register your product(s) at ghostcontrols.com. WARRANTY REGISTER ONLINE WWW.GHOSTCONTROLS.
BL ANK PAGE
SPECIFICATIONS 7 SPECIFICATIONS DTP1 GATE OPERATOR KIT SPECIFICATIONS ■ Compliance: The operator is system certified to be in compliance with UL325 Standard, 7th Edition ■ System Operating Voltage: 12 VDC ■ System Battery Type: Battery Box Kit (ABBT) 1 battery is included ■ System Current: 1-2 Amps is typical when active.
BL ANK PAGE ©Ghost Controls 2019
SYSTEM SAFETY 9 SYSTEM SAFETY GATE OPENER SYSTEMS This manual contains important safety precautions and warnings for both the installer and end users or consumers of this automatic gate opener system. The following warnings and safety are intended to apply to the most common applications but may not apply to all possible installation and applications for these products. To reduce risk of injury or death: I.
SYSTEM SAFETY VEHICULAR GATE STANDARD We recommend that all vehicular gates be constructed and installed in accordance with Active Standard ASTM F2200, Standard Specification for Automated Vehicular Gate Construction. For more information on this standard, contact ASTM directly at http://www.astm.org/Standards/ F2200.htm. WARNING SIGNS The included warning signs must be installed on both the inside and outside of the gate.
S Y S T E M S A F E T Y 11 OPTIONAL PHOTO BEAM OPTIONALPHOTO BEAM OPTIONAL PHOTO BEAM Grey Indicates Potential Entrapement Areas OPTIONAL PHOTO BEAM OPTIONAL PHOTO BEAM OPTIONAL PHOTO BEAM ENTRAPMENT AREA Between gate and post Pinch point between opener and gate Path of the moving gate Leading edge of gate and pinch point between gates in a dual gate installation NOTES Keep hands, feet, and pets away from this area when gate is in motion.
BL ANK PAGE ©Ghost Controls 2019
S Y S T E M O V E R V I E W 13 SYSTEM OVERVIEW IMPORTANT INSTRUCTIONS Thank you for choosing a GHOST CONTROLS® Automatic Gate Opener system, the most innovative gate opener systems available for residential applications on the market today. This manual will guide you through the proper installation and maintenance methods. To reduce the risk of injury or death: READ, UNDERSTAND, AND FOLLOW ALL INSTRUCTIONS CAREFULLY AND COMPLETELY.
SYSTEM OVERVIEW 10 . When planning a system that will allow entry from a busy road or highway, make sure the system is placed far enough from the road to prevent traffic congestion. 11 . Swing gate systems must not open into public access 15 . Swing direction of gate(s). The image (shown in diagram below) indicates the more common “Pull-toOpen” installation and the less common “Push-toOpen” installation. areas or into the road which could cause collision with a moving vehicle. 12 .
P L A N N I N G 15 INSTALLATION PLANNING SITE PLANNING SITE INSTALLATION VIDEO CAN BE FOUND AT GhostControls.com/Support/Installation-Video PREPARE THE GATE Proper installation, care, and ongoing maintenance of the gate is critical to increased usage life of the automatic gate operator system. The following items should be considered and addressed if needed PRIOR to installation of the automatic gate operator system: 1 .
PLANNING NOTE Push-to-Open installations REQUIRE an accessory Push-to-Open bracket kit (AXPO). 7. Mounting location on gate and support post, column, or wall. A. Wooden posts should be at least 6 " x6" in size and set in concrete. B. Metal round posts should be at least 3" in diameter and set in concrete. C. Metal square posts should be at least 4"x 4" in size and set in concrete. D.
P L A N N I N G 17 DETERMINE MOUNTING LOCATION ON GATE AND SUPPORT BAR You must determine where to mount the gate operator vertically on your gate system. Your gate MUST HAVE A HORIZONTAL BAR ON THE GATE TO MOUNT THE FRONT OF OPERATOR TO. Each gate is unqiue and Ghost Controls does not provide this in the kit.
BL ANK PAGE ©Ghost Controls 2019
T O O L S N E E D E D 19 TOOLS NEEDED Corded/Cordless Drill Standard or Metric Wrenches 5/16" Drill Bit 7/32" Drill Bit 7/16" Drill Bit (longer than diameter or thickness of post) Clamp Wire Strippers/Cutters Level Standard or Metric Socket Set Phillips Head Screwdriver Tape Measure ©Ghost Controls 2019
PARTS INCLUDED INCLUDED PARTS IN KIT Post and Rear Mount Hardware Gate and Front Mount Hardware Gate Mount Hardware Front Mount Hardware Rear Mount Hardware Estate Bracket (Qty 1) PBK6BA ©Ghost Controls 2019
P U L L - T O - O P E N 21 PULL TO OPEN INSTALLATION OPERATOR ARM INSTALLATION NOTE Wheels cannot be used with any Ghost Controls® gate opener system! For gates weighing over 200 lbs. ball bearing hinges are recommended. Operator is not for use on solid panel privacy gates.
PULL-TO-OPEN STEP 2. Post bracket pre-assembly. Insert the M10x1.5x75mm bolt and M10 washer through the hole that is closest to the post on the post bracket. Bolt should then go through first pivot bracket, pivot spacer, second pivot bracket, and exit bottom hole of post bracket as shown below. Fasten a M10 washer and M10 locknut on the end of the bolt. DO NOT overtighten the nut because the post bracket may need to be adjusted later. Exploded Assembled STEP 3.
P U L L - T O - O P E N 23 NOTE For round wooden post installations we recommend notching the wooden post for proper installation of the post bracket. Follow the diagram for proper notching of a round post. 4-3/8" Width (4" minimum) 4.5" Height NOTE For 3” and 4” round steel posts, we offer the AX3R AND AX4R round post adapter accessories (sold separately). See illustration using the round post adapter below.
PULL-TO-OPEN STEP 4. Verifying minimum of 4˝ Gate Clearance and finishing rear post mount bracket assembly. If the clearance is less than 4˝, you will need to adjust the pivot brackets so that you have at least 4˝ of clearance. Once the clearances are correct, place the secondary bolt into the pivot bracket as shown. Insert the M10x1.
P U L L - T O - O P E N 25 STEP 5. Drilling rear post bracket holes and bolting. A . With the post bracket still clamped to post, mark the center of the bracket slots. Remove the bracket. B. You will need a 7/16˝ drill bit and drill the (4) holes to mount the rear post bracket to the post. TIP: Drill each hole one at a time and insert a bolt through to ensure that the holes are large enough and all aligned. C.
PULL-TO-OPEN INSTALLING THE CONTROL BOX AND BATTERY BOX FOR YOUR PULL-TO-OPEN SYSTEM STEP 7. Determine the mounting location for the control and battery box. The battery and control box must be located within 4 feet of each other. Then install.
P U L L - T O - O P E N 27 Strain Relief B. Connect the terminal leads of the battery harness to your battery. IMPORTANT SYSTEM WILL NOT OPERATE WITHOUT BATTERY INSTALLED AND CONNECTED AT ALL TIMES. IF USING SOLAR YOU WILL NEED TO HAVE TWO 12V BATTERIES. Connect the battery harness from the control box to the battery. Make sure RED WIRE CONNECTS TO BATTERY’S (+) TERMINAL. (CONNECT FIRST) Make sure the BLACK WIRE CONNECTS TO BATTERY’S (-) TERMINAL.
PULL-TO-OPEN CONNECTING OPERATOR ARM TO CONTROL BOX STEP 9. Insert the operator cable into the control box. A . Route the operator cable through the same strain relief as the battery harness cable and into the control box. B. Connect the operator wires to the control board.
P U L L - T O - O P E N 29 PREPARING THE GATE SYSTEM CONTROLLER The gate system control board provides one convenient place to make all of your system connections and to change any settings that you desire to personalize how your automatic gate opener system operates at your home or property. This main board (shown below) is located inside of the control box of your system and will be referred to in detail through the next few sections.
PULL-TO-OPEN A . DIP SWITCH OPTION Settings. There are four DIP Switches located on the main control board (shown) that must be positioned properly for your particular installation. B. DIP #1 OPEN DIRECTION. The opening direction of the gate operator is determined by DIP#1. DIP Switch # OFF Position 1 Pull-To-Open (Factory Default): Gate is pulled to open into your property. ON Position Push-To-Open Installation: Gate is pushed to open away from your property. C. DIP #2 ALARM WARNING.
P U L L - T O - O P E N 31 E. DIP #4 DUAL (BI-PARTING) GATE OPENING SEQUENCE. The gate opening sequence for dual gate opener systems only is determined by DIP#4. This DIP switch does not apply to single gate opener installations NOTE The SECOND arm will always CLOSE first before the FIRST arm. DIP Switch # OFF Position 4 Delay Open (Factory Default): FIRST arm will open before the SECOND arm.
PULL-TO-OPEN STEP 12. Use the remote transmitter to fully retract the arm. The arm will stop on its own. The arm in the fully retracted position will determine the OPEN position of the gate. NOTE The arm has an internal limit switch that is fixed and is not adjustable. ARM FULLY RETRACTED TURN THE CONTROL BOX OFF STEP 13. Attach the front mount bracket to the operator. The gate must remain in the desired open position.
P U L L - T O - O P E N 33 STEP 14. Attach the FRONT MOUNT AND ESTATE BRACKET to the gate. The gate must remain in the desired open position. OPEN THE GATE TO THE DESIRED OPEN POSITION A . Line up the pre-assembled front mount gate bracket over the center-most bar on your gate and mark the center location of the outermost hole on the gate. WARNING DO NOT SCREW THE OPERATOR ARM IN OR OUT AT THIS POINT. DOING SO CAUSES THE LIMITS TO NOT BE IN THE FULLY OPEN POSITION.
PULL-TO-OPEN B. Install the front mount gate bracket and estate bracket on the gate by aligning the outermost hole of both brackets and inserting (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through both the estate and front mount bracket, as show below. Tighten to secure the brackets to the gate. MAKE SURE GATE IS STILL IN OPEN POSITION (arm must be fully retracted). Front Mount Bracket Estate Bracket install on backside of gate C.
P U L L - T O - O P E N 35 E. Now you can mark and drill the inner most hole on the front mount bracket, shown below. Mark and drill center location of innermost hole CL F. Align the innermost hole of the estate and front mount brackets and insert (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through both holes and tighten to secure the bracket to the gate. YOUR FRONT MOUNT AND ESTATE BRACKET SHOULD NOW BE ATTACHED AND SECURED TO THE GATE. G.
PULL-TO-OPEN PROGRAMMING THE CLOSED LIMIT FOR A PULL-TOOPEN INSTALLATION This is the most common installation. The CLOSED limit is when the operator is extended and the gate is in the closed position. IMPORTANT ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE. THE OPEN POSITION IS SET BY HARDWARE MOUNTING ONLY.
P U L L - T O - O P E N 37 A . Confirm the newly programmed CLOSED limit by pressing the remote transmitter button to activate the gate and confirm the closed position has been set correctly. This limit is stored and remembered even when all of the power sources are removed. B. Repeat STEPS 16-18 if needed to change your desired CLOSED position. C. Test your system with the remote transmitter to make sure it opens and closes without errors.
PULL-TO-OPEN POWERING THE SYSTEM WITH SOLAR STEP 19. Adding a solar panel (optional) to the control box. A . When wiring a Solar Panel you will need to insert the solar wires into the SOLAR SCREW TERMINALS which are located on the PWR INPUT section of the main control board. Once inserted then tighten each screw so that the wires do not come loose and fall out. Please refer to diagram below. DO NOT CONNECT AC TRANSFORMER IF USING SOLAR POWER. Black Operator Arm Battery Harness B.
P U L L - T O - O P E N 39 SETTING AUTOCLOSE TIME ON YOUR GATE The AUTOCLOSE TIME setting determines how long the gate will remain open each time it operates before automatically closing. The factory default setting is off which requires the user to push either a remote transmitter button, keypad code, or push-button to close the gate. NOTE The AUTOCLOSE time period begins once the gate has reached its open limit.
PULL-TO-OPEN CANCELLING AUTOCLOSE TIME ON YOUR GATE NOTE Canceling AUTOCLOSE can only be performed when the gate opener is idle. Cancelling AUTOCLOSE will remove your previous duration setting and force you to pick a new duration the next time you enable AUTOCLOSE. You can use PartyMode® to temporarily disable AUTOCLOSE and the system will retain your current AUTOCLOSE duration when PartyMode® is disabled.
P U S H - T O - O P E N 41 PUSH TO OPEN INSTALLATION OPERATOR ARM INSTALLATION NOTE Wheels cannot be used with any Ghost Controls® gate opener system! For gates weighing over 200 lbs. ball bearing hinges are recommended. Operator is not for use on solid panel privacy gates.
PUSH-TO-OPEN STEP 2. Post bracket pre-assembly. YOU WILL NEED TO MAKE SURE YOU PURCHASE THE PUSH-TO-OPEN BRACKET KIT (AXPO) BEFORE YOU START THIS STEP Insert the M10x1.5x75mm bolt and M10 washer through the hole that is closest to the post on the post bracket. Bolt should then go through first push-to-open bracket, pivot spacer, second push-to-open bracket, and exit bottom hole of post bracket as shown. Fasten a M10 washer and M10 locknut on the end of the bolt.
P U S H - T O - O P E N 43 NOTE For round wooden post installations we recommend notching the wooden post for proper installation of the post bracket. Follow the diagram below for proper notching of a round post. 4-3/8" Width (4" minimum) 4.5" Height NOTE For 3” and 4” round steel posts, we offer the AX3R AND AX4R round post adapter accessories (sold separately). See illustration using the round post adapter below.
PUSH-TO-OPEN STEP 4. Verifying minimum of 4˝ gate clearance and finishing rear post mount bracket assembly. If the clearance is less than 4˝, you will need to adjust the pivot brackets so that you have at least 4˝ of clearance. Once the clearances are correct, place the secondary bolt into the post bracket as shown. Insert the M10x1.
P U S H - T O - O P E N 45 STEP 5. Drilling rear post bracket holes and bolting. A . With the post bracket still clamped to post, mark the center of the bracket slots. Remove the bracket. B. You will need a 7/16˝ drill bit and drill the (4) holes to mount the rear post bracket to the post. TIP: Drill each hole one at a time and insert a bolt through to ensure that the holes are large enough and all aligned. C.
PUSH-TO-OPEN INSTALLING THE CONTROL BOX AND BATTERY BOX FOR YOUR PULL-TO-OPEN SYSTEM STEP 7. Determine the mounting location for the control and battery box. The battery and control box must be located within 4 feet of each other. Then install. NOTE Mount the control box a minimum of 3 feet above the ground to keep dirt and water from damaging the control board and within 4 feet of the operator arm in order for the operator cable to reach the control box. A.
P U S H - T O - O P E N 47 Strain Relief B. Connect the terminal leads of the battery harness to your battery. IMPORTANT YOU NEED A 12V DEEP MARINE/AUTOMOTIVE BATTERY OR THE ABBT BATTERY BOX KIT. SYSTEM WILL NOT OPERATE WITHOUT BATTERY INSTALLED AND CONNECTED AT ALL TIMES. IF USING SOLAR YOU WILL NEED TO HAVE TWO 12V BATTERIES. Connect the battery harness from the control box to the battery.
PUSH-TO-OPEN USED FOR EXTRA STORAGE CAPACITY. CONNECTING OPERATOR ARM TO CONTROL BOX STEP 9. Insert the operator cable into the control box. A . Route the operator cable through the same strain relief as the battery harness cable and into the control box. B. Connect the operator wires to the control board.
P U S H - T O - O P E N 49 PREPARING THE GATE SYSTEM CONTROLLER The gate system control board provides one convenient place to make all of your system connections and to change any settings that you desire to personalize how your automatic gate opener system operates at your home or property. This main board (shown below) is located inside of the control box of your system and will be referred to in detail through the next few sections.
PUSH-TO-OPEN A . DIP SWITCH OPTION Settings. There are four DIP Switches located on the main control board (shown) that must be positioned properly for your particular installation. B. DIP #1 OPEN DIRECTION. The opening direction of the gate operator is determined by DIP#1. DIP Switch # OFF Position 1 ON Position P u l l -To - O p e n ( Fa c t o r y Push-To-Open Installation: Gate is pushed to open away from your Default): Gate is pulled to open property. into your property. C. DIP #2 ALARM WARNING.
P U S H - T O - O P E N 51 E. DIP #4 DUAL (BI-PARTING) GATE OPENING SEQUENCE. The gate opening sequence for dual gate opener systems only is determined by DIP#4. This DIP switch does not apply to single gate opener installations NOTE The SECOND arm will always CLOSE first before the FIRST arm.
PUSH-TO-OPEN STEP 12. Use the remote transmitter to fully retract the arm. The arm will stop on its own. The arm in the fully retracted position will determine the CLOSED position of the gate. NOTE The arm has an internal limit switch that is fixed and is not adjustable. ARM FULLY RETRACTED TURN THE CONTROL BOX OFF STEP 13. Attach front mount bracket to the operator. The gate must remain in the desired closed position.
P U S H - T O - O P E N 53 STEP 14. Attach the FRONT MOUNT AND ESTATE BRACKET to gate. The gate must remain in the desired closed position CLOSE THE GATE TO THE DESIRED CLOSED POSITION A . Line up the pre-assembled front mount gate bracket over the center-most bar on your gate and mark the center location of the outermost hole on the gate. NOTE DO NOT SCREW THE OPERATOR ARM IN OR OUT AT THIS POINT. DOING SO CAUSES THE LIMITS TO NOT BE IN THE FULLY CLOSED POSITION.
PUSH-TO-OPEN B. Install the front mount gate bracket and estate bracket on the gate by aligning the outermost hole and inserting (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through gate and front mount bracket, as show below. Tighten to secure the brackets to the gate. MAKE SURE GATE IS STILL IN CLOSED POSITION (arm must be fully retracted). Estate Bracket install on backside of gate Front Mount Bracket C. Disconnect operator from gate bracket and swing away from the gate.
P U S H - T O - O P E N 55 F. Align the innermost hole of the estate and front mount brackets and insert (1) M8 x 65mm flat washer, and (1) M8 nylon locknut through both holes and tighten to secure the bracket to the gate. YOUR FRONT MOUNT AND ESTATE BRACKET SHOULD NOW BE ATTACHED AND SECURED TO THE GATE. G. Align and attach arm of operator to the secured front mount bracket, as shown below. Make sure all parts installed during installation are tightened down.
PUSH-TO-OPEN PROGRAMMING THE OPEN LIMIT FOR A PUSH-TO-OPEN INSTALLATION The OPEN limit is when the operator is extended and the gate is in the closed position. IMPORTANT ONLY THE OPERATOR ARMS’ EXTENDED LIMIT IS ADJUSTABLE AND CAN BE SET WITH THE CONTROL BOARD. THE ARMS’ RETRACTED POSITION IS FIXED AND IS NOT ELECTRONICALLY ADJUSTABLE. THE CLOSED POSITION IS SET BY HARDWARE MOUNTING ONLY.
P U S H - T O - O P E N 57 A . Confirm the newly programmed OPEN limit by pressing the remote transmitter button to activate the gate and confirm the closed position has been set correctly. This limit is stored and remembered even when all of the power sources are removed. B. Repeat STEPS 16-18 if needed to change your desired OPEN position. C. Test your system with the remote transmitter to make sure it opens and closes without errors.
PUSH-TO-OPEN POWERING THE SYSTEM WITH SOLAR STEP 19. Adding a solar panel (optional) to the control box. A . When wiring a Solar Panel you will need to insert the two solar wires into the SOLAR SCREW TERMINALS which are located on the PWR INPUT section of the main control board. Once inserted then tighten each screw so that the wires do not come loose and fall out. Please refer to diagram below. DO NOT CONNECT AC TRANSFORMER IF USING SOLAR POWER. Black Operator Arm Battery Harness B.
P U S H - T O - O P E N 59 SETTING AUTOCLOSE TIME ON YOUR GATE The AUTOCLOSE TIME setting determines how long the gate will remain open each time it operates before automatically closing. The factory default setting is off which requires the user to push either a remote transmitter button, keypad code, or push-button to close the gate. NOTE The AUTOCLOSE time period begins once the gate has reached its open limit.
PUSH-TO-OPEN CANCELLING AUTOCLOSE TIME ON YOUR GATE NOTE Canceling AUTOCLOSE can only be performed when the gate opener is idle. Cancelling AUTOCLOSE will remove your previous duration setting and force you to pick a new duration the next time you enable AUTOCLOSE. You can use PartyMode® to temporarily disable AUTOCLOSE and the system will retain your current AUTOCLOSE duration when PartyMode® is disabled.
T R OPUUBSLH ES - THOO-O OTPI N EN G 61 TROUBLESHOOTING GUIDE FOR HELPFUL VIDEOS VISIT: MYGHOSTCONTROLS.FORCE.COM/SUPPORT/S/. LEARN NEW REMOTE 2018-08 DO NOT USE this procedure if you already have a remote that operates the gate and just want to add an additional remote. If you want to add an additional remote, please refer to the remote manual for adding additional remote for your system. 1. Press and hold the ‘LEARN XMTR’ until the alarm sounds and the yellow LED stays ON. Release the button. 2.
BL ANK PAGE ©Ghost Controls 2019
H A R D W I R E D A C C . 63 CONNECTING OPTIONAL HARDWIRED ACCESSORIES CONNECTING TO CONTROL BOARD NOTE Please refer to the manufacturers manual or website for more detailed instructions on how to connect and use accessories from other manufacturers with your Ghost Controls® gate opener. PREPARING CONTROL BOX FOR ACCESSORY WIRING Make sure the power is turned off which is located on bottom of the control board before wiring.
HARDWIRED ACC. ■ Active — Signal must go from INACTIVE then ACTIVE for the system to recognize the input and respond accordingly.EX: OPEN > STOP > CLOSE > STOP > OPEN >... OPEN INPUT (OPEN): Use this terminal for Ghost Controls Vehicle Detector (AXXV). Active — OPENS gate to full open limit and prevents it from closing. CLOSING-REVERSE INPUT (CLS-RVRS): Use this terminal with photo eye beams or safety edge. ■ Active — Prevents gate from CLOSING or reversing to open limit if it was CLOSING.
M A N U A L 65 MANUAL GATE OPERATION EVERY USER MUST KNOW THESE STEPS The gate can be opened or closed manually by releasing the front mount from the gate. You must disconnect the operator only after the operator power switch is OFF and the gate is NOT moving. If you have the accessory ZombieLock® installed, this lock should be manually disengaged with the key because removing power does not unlock this lock. 1 .
ACCESSORIES ACCESSORIES GHOST CONTROLS® genuine accessories are designed to provide complete control and superior convenience for you and your family with your automatic gate opener. These products are specifically engineered to easily integrate into your system and grant you access to additional capabilities and control of your gate opener. All of these accessories are available from your local dealer and are backed by the same reliable warranty that your gate operator is designed to meet.