Spec Sheet

Gillette Generators, Inc.
2921 Thorne Dr. Elkhart, IN 46514 Ph: 574-264-9639 Fax: 574-262-1840 Web: www.gillettegenerators.com spc4-180810
1
60 HZ MODEL
SP-3500
All generator sets are USA prototype built and thoroughly tested.
Production models are USA factory built and 100% load tested.
UL2200, UL1446, UL508, UL142, UL498
NFPA 110, 99, 70, 37
All generator sets meet NFPA-110 Level 1, when equipped with the
necessary accessories and installed per NFPA standards.
NEC 700, 701, 702, 708
NEMA ICS10, MG1, ICS6, AB1
ANSI C62.41, 27, 59, 32, 480, 40Q, 81U, 360-05
ASCE 7-05 & 7-10
All generator sets meet 180 MPH rating.
EPA 40CFR Part 60, 1048, 1054, 1065, 1068
RATINGS: All three phase gen-sets are 12 lead windings, rated at .8 power factor. 120
°
C “STANDBY RATINGS” are strictly for gen-sets that are used for back-up
emergency power to a failed normal utility power source. This standby rating allows varying loads, with no overload capability, for the entire duration of utility power
outage. All gen-set power ratings are based on temperature rise measured by resistance method as defined by MIL-STD 705C and IEEE STD 115, METHOD 6.4.4. All
generators have class H (180°C) insulation system on both rotor and stator windings. All factory tests and KW/KVA charts shown above are based on 120°C (standby) R/R
winding temperature, within a maximum 40°C ambient condition. Generators operated at standby power ratings must not exceed the temperature rise limitation for class H
insulation system, as specified in NEMA MG1-22.40. Specifications & ratings are subject to change without prior notice.
LIQUID COOLED NAT. GAS ENGINE GENERATOR SET
GENERATOR RATINGS
LIQUID PROPANE GAS FUEL NATURAL GAS FUEL
GENERATOR MODEL
VOLTAGE
PH HZ
120°
°°
°C RISE STANDBY RATING 120°
°°
°C RISE STANDBY RATING
L-N L-L KW/KVA AMP KW/KVA AMP
SP-3500-3-2
120 208 3 60 260/325 903 350/438 1216
SP-3500-3-3
120 240 3 60 260/325 782 350/438 1054
SP-3500-3-4
277 480 3 60 260/325 391 350/438 527
SP-3500-3-5
127 220 3 60 260/325 854 350/438 1150
SP-3500-3-16
346 600 3 60 260/325 313 350/438 421
“OPEN” GEN-SET
There is no enclosure, so gen-set must be
placed within a weather protected area,
un-inhabited by humans or animals, with
proper ventilation. Silencer not supplied,
as installation requirements are not
known. However, this item is available as
optional equipment.
“LEVEL 2” HOUSED GEN-SET
Full aluminum weather protection and superior
sound attenuation for specific low noise
applications. Critical grade muffler is standard.
Model
STANDBY
120ºC RISE
HZ LPG N.G.
SP
-
3500
-
60 HERTZ
60 260 350