Use and Care Manual

6
Fix Stand
(7W050-4)
2mm
Hex. Spanner
Cylinder Assembly
(11~14)
18
Special Spanner
(7W050-1)
(C) Maintenance Steps For Cylinder Assy.
After disassembling the Shifting Post (21), use Special Spanner
(7W050-1) to loosen Locking Cap (18).
Loosen screw using 2mm Hex. Spanner and take out Cylinder
Assembly (11~14).
Caution :
When reassemble Cylinder Assembly (11~14), rotate the
Spindle Assembly (35~40) by hand to see if it spins smoothly
and tighten Locking Cap (18). Check Spindle Assembly
(35~40) again and if it does not spin freely, disassemble and
investigate Cylinder Assembly (11~14).