InstallatIon
IntroductIon
This manual describes the operational features of the Reach-In Mug Chiller model MFV24. Please review this information
before attempting installation and operation.
Long term, trouble-free service will follow if good housekeeping and maintenance procedures are followed. Thank you for
selecting Glastender, Inc. products.
utIlIty requIrements and connectIons
Electrical: 115 Volt AC, 1 Phase, 60 Hz, 8.55 Full Load Amps. A separate 15 Amp circuit is recommended. A 6-foot
grounded cord is included.
Plumbing: Automatic condensate evaporator is included. No drain connection required.
uncratIng and start-uP InstructIons
All Reach-In Mug Chiller models are shipped in one carton. These steps should be followed:
1. If legs or casters are included, bolt them to the base with the bolts provided.
2. Unwrap power cord from base.
3. Position the Reach-In Mug Chiller and level and/or seal as required (see page 2).
4. Install shelves.
5. Plug into 115 volt AC outlet.
6. Load with mugs, glasses, plates, etc.
7. Your Glastender Reach-In Mug Chiller is now ready for use.
oPeratIon
The Reach-In Mug Chiller is designed to chill mugs, glasses, plates, etc. that will appear “frosted” when removed. The operating
temperature range of 0°F(-18°C) to 35°F(2°C).
The Reach-In Mug Chiller should be filled with dry, room-temperature mugs, glasses, plates, etc. to allow maximum chilling.
During business hours, the Reach-In Mug Chiller can be loaded with additional dry, room-temperature mugs, glasses, plates,
etc. Allow 30 minutes for chilling.
The Reach-In Mug Chiller includes an automatic defrost system. Defrosting will occur every six hours for approximately 20
minutes. During the defrost cycle, the fan inside the Reach-In Mug Chiller will turn off and a small amount of mist may appear
if the door is opened.
There is also a manual defrost system controlled by a switch located on the front left bottom of the Reach-In Mug Chiller. This
is used when there is ice or snow accumulation inside. An end-of-the-day or weekly schedule can be established for the activa-
tion of this manual defrost cycle.
When the manual defrost switch is pushed, a light will turn on and the Reach-In Mug Chiller will go into a six-hour defrost.
After six hours, the Reach-In Mug Chiller will resume normal operation.
If the manual defrost switch is accidentally pushed, the defrost cycle can be terminated by unplugging the power cord for
three seconds.