Manual

4
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780
800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com
WIrIng dIagram
10
11
2
1
14
15
6
13
5
12
8
7
9
3
5
4
6
16
3
Mug Froster
MFV Wiring
BL
O = Orange
W/R = White W/ Red
W = White
P = Purple
R = Red
P
BR = Brown
BL = Blue
B = Black
LEGEND
4
3
2
1
P
RECOMMENDED
15 AMP. SERVICE
115 VOLT
POWER
NEUTRAL
B
B
GROUND
W
P
P
5
W/R
P
B
7
A
2
5
W
115V, Single Phase, 60Hz, 3 wire.
Condensing Unit Fan Motor
TOTAL AMPS
Evaporator Fan Motor
Compressor
All wires are 16 Gauge
8.85
.53 AMP
.82 AMP
7.60 AMP
ELECTRICAL RATINGS
W
1/26/95
COMPRESSOR WIRING
C
M
W
M
S
B
1
2
M
3
1
4
2
R
OPENS ABOVE +45°F
BR
O O
OVERLOAD PROTECTOR, 1/3hp R404a, TECUMSEH 12
FAN BLADE, CONDENSER, 5 BLADE
RELAY, 1/3hp R404a, TECUMSEH COMPRESSOR
START CAPACITOR, 1/3hp R404a, TECUMSEH COMPRESSOR
13
14
15
W
W
W
DEFROST HEATER, 115v
SWITCH, MANUAL DEFROST, START AND CYCLE TEST
MANUAL DEFROST TIMER, 6 HOUR
COMPRESSOR, 1/3 hp, R404a, (TECUMSEH) AFTER 01/2002
CONDENSER, FAN MOTOR, 6W
SENSOR, DEFROST
DEFROST TIMER, AUTOMATIC, 115v 6-HOUR, PARAGON
MOTOR, EVAPORATOR FAN, 115v
THERMOSTAT
RELAY, EVAPORATOR FAN, 115v, MUG FROSTER
9
10
11
5
6
8
7
3
4
2
W
W
W
W
LIGHT, MANUAL DEFROST, RED, 125v1
ITEM
DESCRIPTION
07000128
07000155
06001380
07000168
07000156
07000257
07000169
07000165
06001397
07000175
06001449
06001445
07000621
07000166
07000171
MT#
GT-033000
GT-034112
GT-031207
GT-032206
GT-032803
GT-033413
GT-033001
GT-033401
GT-034704
GT-035107
GT-035114
GT-035026
GT-034105
GT-034907
GT#
W
B
HEATER
GLASS DOOR
OPTIONAL
FOR MFV-24
16
EVAPORATOR FAN BLADE, 5 BLADE, BLACK
GT-032804 09000298
P