User manual

16
Protection level IP20
Environment -20 ~ +40 °C, <93 % RH
Dimensions Ø22 x 63.5 mm
Mounting hole diameter
(Hollowproles)
17 mm
Mounting hole distance
(Surfacemount)
28 mm
Weight 228 g
Ta b . 2 : Specications
3 Intended Use
IP20
Wedonotpermitusingthedeviceinotherwayslikedescribedin
chapter“DescriptionandFunction“and„SafetyInstructions“.This
productisprotectedagainstmediumsizedforeignobjects,butnotagainst
water ingress. Not attending to these regulations and safety instructions
mightcausefatalaccidents,injuries,anddamagestopersonsandproperty.
4 Preparation
Comparethespecic ationsofalluseddevicestoensurecompatibilit y.
Checkthescopeofdeliveryforcompletenessandintegrity.
5 Installation
Risk of electric shock
LetopencableendsONLYassemblebyexperienced
electrician.
 Cutoffpowersupplybeforeanyworkontheproduct,
switch off safety fuse and secure against reconnection.
Assure and check the absence of voltage before any
workontheproduct.
Connect the daylight sensor in one of the ways described below.
Fi g. 14: Installation