GSZC18 Installation

I
MPORTANT
S
AFETY
I
NSTRUCTIONS
The following symbols and labels are used throughout this
manual to indicate immediate or potential safety hazards. It is
the owners and installers responsibility to read and comply with
all safety information and instructions accompanying these sym-
bols. Failure to heed safety information increases the risk of
personal injury, property damage, and/or product damage.
CONDENSING UNIT
HEAT PUMP
INSTALLATION & SERVICE REFERENCE
© 2009-2014, 2016-2018
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
P/N: IOG-4009G Date: January 2018
is a registered trademark of Maytag Corporation or its related companies and is used
under license to Goodman Company, L.P., Houston, TX. All rights reserved.
HIGH VOLTAGE!
D
ISCONNECT
ALL
POWER
BEFORE
SERVICING
.
M
ULTIPLE
POWER
SOURCES
MAY
BE
PRESENT
. F
AILURE
TO
DO
SO
MAY
CAUSE
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
WARNING
S
CROLL
EQUIPPED
UNITS
SHOULD
NEVER
BE
USED
TO
EVACUATE
THE
AIR
CONDITIONING
SYSTEM
. V
ACUUMS
THIS
LOW
CAN
CAUSE
INTERNAL
ELECTRICAL
ARCING
RESULTING
IN
A
DAMAGED
OR
FAILED
COMPRESSOR
.
CAUTION
O
NLY
PERSONNEL
THAT
HAVE
BEEN
TRAINED
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
(
HEREINAFTER
, “
SERVICE
”)
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
SHOULD
SERVICE
THE
EQUIPMENT
. T
HE
MANUFACTURER
WILL
NOT
BE
RESPONSIBLE
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
ARISING
FROM
IMPROPER
SERVICE
OR
SERVICE
PROCEDURES
. I
F
YOU
SERVICE
THIS
UNIT
,
YOU
ASSUME
RESPONSIBILITY
FOR
ANY
INJURY
OR
PROPERTY
DAMAGE
WHICH
MAY
RESULT
. I
N
ADDITION
,
IN
JURISDICTIONS
THAT
REQUIRE
ONE
OR
MORE
LICENSES
TO
SERVICE
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
ONLY
LICENSED
PERSONNEL
SHOULD
SERVICE
THE
EQUIPMENT
. I
MPROPER
INSTALLATION
,
ADJUSTMENT
,
SERVICING
OR
REPAIR
OF
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
,
OR
ATTEMPTING
TO
INSTALL
,
ADJUST
,
SERVICE
OR
REPAIR
THE
EQUIPMENT
SPECIFIED
IN
THIS
MANUAL
WITHOUT
PROPER
TRAINING
MAY
RESULT
IN
PRODUCT
DAMAGE
,
PROPERTY
DAMAGE
,
PERSONAL
INJURY
OR
DEATH
.
S
HIPPING
I
NSPECTION
Always keep the unit upright; laying the unit on its side or top
may cause equipment damage. Shipping damage, and subsequent
investigation is the responsibility of the carrier. Verify the model
number, specifications, electrical characteristics, and accessories
are correct prior to installation. The distributor or manufacturer
will not accept claims from dealers for transportation damage or
installation of incorrectly shipped units.
C
ODES
& R
EGULATIONS
This product is designed and manufactured to comply with na-
tional codes. Installation in accordance with such codes and/or
prevailing local codes/regulations is the responsibility of the in-
staller. The manufacturer assumes no responsibility for equip-
ment installed in violation of any codes or regulations. Rated
performance is achieved after 20 hours of operation. Rated per-
formance is delivered at the specified airflow. See outdoor unit
specification sheet for split system models or product specifica-
tion sheet for packaged and light commercial models. Specifica-
tion sheets can be found at www.goodmanmfg.com for
Goodman
®
brand products or www.amana-hac.com for Amana
®
brand products. Within either website, please select the resi-
dential or commercial products menu and then select the
submenu for the type of product to be installed, such as air con-
ditioners or heat pumps, to access a list of product pages that
each contain links to that model’s specification sheet.
The United States Environmental Protection Agency (EPA) has
issued various regulations regarding the introduction and dis-
posal of refrigerants. Failure to follow these regulations may
harm the environment and can lead to the imposition of sub-
stantial fines.
IOG-4009G
1/2018
“IMPORTANT - This product has been designed and manufactured to meet ENERGY STAR
®
criteria for energy efficiency when matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical to achieve rated capacity and
efficiency. Installation of this product should follow the manufacturers refrigerant charging
and air flow instructions. Failure to confirm proper charge and air flow may reduce
energy efficiency and shorten equipment life.
Proper sizing and installation of equipment is critical to achieving optimal performance. Split system
air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR®
criteria. Ask your contractor for details or visit www.energystar.gov.