Datasheet

GOSSEN METRAWATT GMBH 3
SSP-KONSTANTER, Series 62 N and Series 64 N
Computer Controlled Laboratory Power Supplies
Extreme Measurement Value Memory
The MIN-MAX function causes automatic acquisition and storage
to memory of minimum and maximum voltage and current
measurement values.
Memory Function
Device configurations can be saved to, and recalled from the memory
with battery backup. The memory has two storage areas:
10 memory locations for complete configurations
245 memory locations for the sequence function (voltage set-
point USET, current setpoint ISET, dwell time TSET)
Sequence Function
The sequence function allows for automatic recall of settings
which have been saved to the sequence memory.
The sequence function includes the following parameters:
START = beginning memory location address
STOP = ending memory location address
REPETITION = number of sequence repetitions
(1 to 255 or 0 = continuous repetition)
TSET = dwell time specific to memory location
(10 ms to 99.99 s)
TDEF = dwell time independent of memory location
(10 ms to 99.99 s)
Application Example:
Generation of a voltage profile in accordance with DIN 40839
(automotive electrical system while cranking the starter motor)
Note:
Maintenance of voltage rise and decay times can only be assured
within a limited load impedance range.
Applicable Standards and Regulations
Order Information
Software
Installation Accessories
IEC 61010-1/EN 61010-1/
VDE 0411-1
Safety regulations for electrical measurement, control
and laboratory devices
EN 60529
VDE 0470 Part 1
Test instruments and test procedures
protection provided by enclosures (IP code)
DIN EN 61326
VDE 0843 Part 20
Electrical equipment for measurement, control and
laboratory use - EMC requirements
U [V]
12
6
4.5
5
t [ms]
15 5 2000 10
Description (short name) Article number
62 N 52 RU 25 P K344A
62 N 52 RU 50 P K345A
64 N 52 RU 100 P K352A
64 N 52 RU 150 P K362A
62 N 80 RU 12.5 P K341A
62 N 80 RU 25 P K343A
64 N 80 RU 50 P K351A
64 N 80 RU 75 P K361A
IEEE488/RS232 interface, for SSP-62/64N-BZ3 K382A
RS232 interface, for SSP-62/64N-BZ3 K383A
Type Designation Article No.
K930D LabView, device driver for SSP-KONSTANTER
series 120 / 240 / 320, and
series 500 / 1000 / 2000 / 3000
K930D
K930E LabWindows / CVI, device driver for SSP-KONSTANTER
series 120 / 240 / 320, and
series 500 / 1000 / 2000 / 3000
K930E
K930F HPVEE / VXI PnP, device driver for SSP-KONSTANTER
series 120 / 240 / 320, and
series 500 / 1000 / 2000 / 3000
K930F
Description Note Article No.
Bus Cable RS-232, 2 m For connecting a device to an RS-232
interface (extension cable 9-pin socket /
9-pin plug)
GTZ 3241
000 R0001
Bus Cable IEEE / IEEE, 2 m For connecting a device to the IEEE-488 bus
system
K931A