Datasheet

GOSSEN METRAWATT GMBH 5
SSP-KONSTANTER, Series 62 N and Series 64 N
Computer Controlled Laboratory Power Supplies
Ambient Conditions
Climatic category KYG per DIN 40 040
Temperature range operation: 0 bis 40 °C
storage: –20 bis +70 °C
Humidity operation: 75 % relative humidity;
no condensaion
storage: 65 % relative humidity
Cooling by integrated fan
(2-stage temperature-controlled)
air inlet: side panels
air outlet: rear panel
Operating noise sound pressure level at a distance of 30 cm
for fan slow / fast
62 N: 64 N:
front 18 / 28 dBA 20 / 30 dBA
rear 23 / 35 dBA 26 / 38 dBA
left, right 20 / 30 dBA 26 / 36 dBA
Mechanical Characteristics
Device Type
Benchtop device, suitable for rack mounting
Dimensions
(W x H x D) see also dimensional drawings
62 N: 19" x 2 std. height units x 500 mm
64 N: 19" x 4 std. height units x 500 mm
Weight 62 N: 500 W: approx. 12 kg
1000 W: approx. 13 kg
64 N: 2000 W: approx. 22 kg
3000 W: approx. 28 kg
Interface RS 232C (optional)
approx. 0.1 kg
Interface IEEE 488 /
RS 232C (optional) approx. 0.14 kg
Terminals (rear panel)
Mains input 62 N: 10-A-IEC inlet connector
with earth contact (L + N + PE)
64 N: 5-pin screw terminal block for
cable connection
0.75 ... 2.5 mm
2
(3 L + N + PE)
Output Rails with drill holes for M8 screws and
4 mm diameter drill holes
Analog interface
14-pin plug connector with screw terminals
Interface Options
a) RS 232C
b) IEEE 488/RS 232C
RS 232C Interface (option a), b))
9-pin sub-D socket connector
DIN 41652
Pin Assignment
Pin 2: TXD (transmitted data)
Pin 3: RXD (received data)
Pin 5: GND (Earth)
Figure 1 Connection cable for serial interface
IEC 625 / IEEE 488 interface (option b))
24-pin IEEE 488 socket connector
IEC 625.1, IEEE 488.1
Pin assignment
TxD_IN 2
3
5
RxD_IN
GND_IN
2 RxD
3 TxD
5 GND
SSP
9-pin sub-D plug9-pin sub-D connector
IN
RS 232
PC/controller
COM1/COM2
For twisting with
opposite cables
Remote Enable
Data Bus
Shield connected
to earth
Attention
Service Request
Interface Clear
Not Data Accepted
Data Valid
End or Identify
Data Bus
Not Ready for Data