8 Single Measurements
8.1 General
The desired measurement is selected with the help of the green
pointer on the rotary switch and the green semicircle.
The respective measurement is configured with the help of
the softkeys. The parameter settings can be accessed by
pressing the softkey with the symbol shown at the right.
The measurement type parameter displayed in each case
in the footer can be changed directly using the key
sh
own at the right without having to exit the measuring
view.
The selection of
polarity
for line voltage at the test socket
can be changed directly using the
key shown at the right
without having to exit the measuring view.
No limit values can be specified for single measurements, and
thus there is no evaluation.
Checking is performed before each measurement in order to
assure a trouble-free sequence, and to prevent any damage to
the DUT.
Single measurements can be saved to memory. The assignment
of
an ID number is possible to this end.
Single measurements can be combined into measurement
se
ries.
Mains power can be connected to the DUT with the desired
polarity by making a pre-selection in the parameter settings.
Measurement Status – Progress Bar
Measurement standstill (static line)
Measurement in progress (space is gradually filled in, pulsating)
Select parameters
Measuring View, Single Measurements
Selecting measurement/connection type
Adjust test current
Rest offset to 0
Offset
Test current
Measurement/connection type
q
Measurement
– Start
– Stop
Probes/sensors: green = connected to test instrument
Current measured value
Scroll through parameter pages
Select measuring parameter directly
Select measuring parameter directly
Select measuring parameter directly
Accept changes
Measuring Parameters Display, Single Measurements
and jump back to measuring view
Current/maximum number of parameter pages
ESC: discard change
and jump back to measuring view
Selected
parameter value
Selectable
parameter
Delete character
Accept character at cursor
Scroll left
to left of the cursor in display
Accept entry
Scroll up
Scroll down
and exit keyboard
Discard entry
and exit keyboard
position
Scroll right
Display keyboard > select/acknowledge digits
/ hide keyboard > edit display value
Numeric Entry (for parameters UISO(set), Offset ...) via Softkeys with the SECUTEST BASE(10)
Delete character to the left
of the cursor in the display
Accept entry
and exit keyboard *
Numeric Entry (for parameters UISO(set), Offset ...) via Touch-Screen Keyboard with the SECUTEST PRO (feature E01)
* Also via assigned softkey
PRINT
ESC
HELP
MEM
PRINT
ESC
HELP
MEM
PRINT
ESC
HELP
MEM
Figure 8 Configuring Single Measurements (parameters entry and display)