User Manual

76 GMC-I Messtechnik GmbH
12 Characteristic Values
Func-
tion
Measured
Quantity
Display Range /
Nominal Range of
Us
e
Reso-
lution
Nominal
Vo
ltage
U
N
Open-
Circuit
Voltage
U
0
Nom.
Current
I
N
Short-
Circuit
Current
I
K
Int.
Resis-
tance
R
I
Ref.
Resis-
tance
R
REF
Measuring
Uncertainty
1
Intrinsic Error
1
Overload
Capacity
Value Time
Tests, 62638 (DIN VDE 0701-0702) / IEC 62 353 (VDE 0751)
Protective
conductor
resistance
R
PE
1 999 m 1 m
< 24 V
AC
or DC
> 200 mA
AC
/ DC
> 10 A AC
5
>35 AAC
11)
(15% r
dg.+ 10 d)
> 10 d
> 10.0 :
(10% r
dg.+ 10 d)
(10% rdg.+ 10 d)
> 10 d
264 V
250 mA
16 A
5
Cont.
1.00 … 9.99 10 m
10.0 30.0
100 m
>42 AAC
11)
15 s
Insulation
resistance
9
RISo
10 999 k 1 k
50 500
V DC
1.0 • U
N
1.5 • U
N
> 1mA < 2 mA
(5% r
dg.+ 4 d)
> 10 d
(2.5% rdg.+2 d)
> 10 d
264 V Cont.
1.00 9.99 M 10 k
10.0 99.9 M 100 k
20 M:
(10% r
dg.+ 8 d)
20 M:
(5% rdg.+4 d)
100 300 M 1 M
Leakage current
alternative
measur
ement
2
IPE, IB, IG, IA
0.0 ... 99 A 1 A
50 ...
250 V~
20/+10%
< 1.5 mA
> 150 k
1 k
10
(5% rdg.+ 4 d) > 10 d
> 15 mA:
(10% rdg.+ 8 d)
(2% rdg.+2 d) > 10 d
> 15 mA:
(5% rdg.+ 4 d)
264 V Cont.
100 ... 999 A 1 A
1.00 ... 9.99 mA 10 A
10.0 ... 30.0 mA 100 A
Leakage current
direct
measur
ement
3
IPE, IB, IG, IA, IP
Only Ip: 0.0 ...
99.9 A
100 nA
1 k
10
1 k
(5% r
dg.+ 4 d)
> 10 d
(2.5% rdg.+2 d)
> 10 d
264 V Cont.
0.0 ... 99 A 1 A
100 ... 999 A 1 A
1.00 ... 9.99 mA 10 A
10.0 ... 30.0 mA 100 A
Leakage current
differential
c
urrent
measurement
4
IPE, IB, IG
0 ... 99 A 1 A
(5% r
dg.+ 4 d)
> 10 d
(2.5% rdg.+2 d)
> 10 d
264 V Cont.
100 ... 999 A 1 A
1.00 ... 9.99 mA 10 A
10.0 ... 30.0 mA 100 A
Function Test at Test Socket
Line voltage
U
L–N
10
100.0 240.0 V~ 0.1 V
(2 % rdg.+2 d)
264 V Cont.
Load current I
L
0 16.00 A
RMS
10 mA
(2 % rdg.+2 d)
16 A Cont.
Active power P
0 3700 W 1 W
(5 % rdg.+10 d)
> 20 d
264 V Cont.
20 A 10 min
Apparent power S
0 4000 VA 1 VA Calculated value, U
L–N
• I
V
(5 % rdg.+10 d)
> 20 d
Power factor PF
with sinusoidal
waveform: cos
0.00 1.00 0.01 Calculated value, P / S, display > 10 W (10 % rdg.+5 d)
t
A
PRCD
Time to trip
0.1 ... 999 ms 0.1 ms 30 mA

5 ms
V–COM
Probe voltage
(probe P1 to PE)
, and
0.0 99.9 V
100 ... 250 V
100 mV
1 V
3 M
(2 % rdg.+2 d)
300 V
,
and
Cont.
Measuring
voltage
(V–COM
sockets
6
, and
1 M
(2 % rdg.+2 d)
> 45 Hz ... 65 Hz
(2 % rdg.+5 d)
> 65 Hz ... 10 kHz
(5 % rdg.+5 d)
> 10 kHz ... 20 kHz
Leakage current
via AT3-IIIE
adapter Z745S
6 8
0.00 ... 0.99 mA
0.01 mA
(2 % rdg.+2 d)
> 10 d
without adapter
253 V Cont.
1.0 ... 9.9 mA
0.1 mA
10 ... 20 mA
1 mA
Temperature
with Pt100
- 200,0 ...
+ 850.0 C
0.1 C < 20 V – 1.1 mA (
2% rdg.+1 C) 10 V Cont.
Temperature
with Pt1000
- 150,0 ...
+ 850.0 C