Reference Ranges
Line voltage 230 V AC 0.2%
Line frequency 50 Hz 2 Hz
Waveform
Sine (deviation between effective and rectified value < 0.5 %)
Ambient temperature + 23 C 2 K
Relative humidity 40 60%
Load resistance Linear
Nominal Ranges of Use
Nominal line voltage 100 V 240 V AC
Nom. line frequency 50 Hz ... 400 Hz
Line voltage waveform
Sinusoidal
Temperature 0 C + 40 C
Ambient Conditions
Storage temperature 20 C + 60 C
Relative humidity Max. 75 %, no condensation allowed
Elevation Max. 2000 m
Deployment Indoors, except within
specified ambient
conditions
In order to avoid deviations on account of high temperature varia-
tions, e. g. after transport in low outside temperatures and subse-
quent operation in a warm indoor environment, we advise you to
wait un
til the test instrument has acclimatized before starting
measurements.
If the test instrument is colder th
an the ambient air, condensation
may occur at high humidity. This means that condensed water
may deposit on components resulting in the development of par-
asitic capacitances and resistances whi
ch, in turn, affect the mea-
suring circuit and measuring accuracy.
Power Supply
Supply network TN, TT or IT
Line voltage 100 V 24
0 V AC
Line frequency 50 Hz ... 400 Hz
Power consumption 200 mA test: approx. 32 VA
10 A test: approx. 105 VA
Mains to test socket
(e. g. function test) Continuous max. 3600 VA, power is con-
ducted through the instrument only,
switching capacity: 16
A, ohmic load
for currents > 16 A AC please use the
adapt
er AT3-IIS32 (Z745X)
Electrical Safety
Protection class I per IEC 61 010-1/DIN EN 61 010-1/
VDE 0411-1
Nominal voltage 230 V
Test voltage 2.3 kV AC 50 Hz or 3.3 kV DC
(mains circuit / test socket to mains PE ter-
minal, USB, finger contact, test probe P1,
t
est socket)
Measuring category 250 V CAT II
Pollution degree 2
Safety shutdown
At DUT differential current of > 10 mA,
shutdown time: < 100 ms,
can also be set to > 30 mA
with following probe current during:
– Leakage current meas.: > 10 mA~/< 5 ms
– Protective conductor resistance meas.:
> 250 mA~/< 1 ms
in the event of a continuous flow of current
I > 16.5 A
Fuse links Mains fuses: 2 ea. FF500 V/16 A
Probe fuse: M250 V/250 mA
SECUTEST BASE10/PRO
SECULIFE ST BASE: one additional
FF500 V/16 A FF
Electromagnetic Compatibility
Product Standard DIN EN 61326-1
Interference
emission
Class
EN 55011 B
Interference
im
munity
Test Value Evaluation criterion
EN 61000-4-2 Contact/atmos. – 4 kV/8 kV A
EN 61000-4-3 3 V/m or 1 V/m A
EN 61000-4-4 1 kV B
EN 61000-4-5 1 kV or 2 kV A
EN 61000-4-6 3 V/m A
EN 61000-4-11 0.5/1/25 periods A
250 periods C
USB Data Interface
Type USB slave for connection to a PC
Type 2 ea. USB master,
for data entry devices* with HID-Boot interface,
for USB flash drive for data backup,
for USB flash drive for saving
reports as BMP files for printers*
* compatible devices see section 14
As of firmware version 1.6.0: In the remote operating mode, the test
instrument can be controlled via the USB slave data interface.
Pertinent interface commands are available upon request.
Bluetooth
®
2.1 + EDR Data Interface
(SECUTEST PRO BT (comfort) or feature M01 only)
Mechanical Design
Display 4.3" multi-display (9.7 x 5.5 cm), backlit,
480 x 272 pixels
at 24 bit color depth (true color)
Dimensions W x H x D: 295 x 145 x 150 mm
Height with handle: 170 mm
Weight SECUTEST BASE(10)/PRO: appr
ox. 2.5 kg
SECULIFE ST BASE 25: approx. 4.0 kg
Protection Housing: IP 40
Test socket: IP 20 per DIN VDE 0470, part
1/EN 60 529
Table Excerpt Regarding Significance of IP Codes
IP XY
(1
st
digit X)
Protection Against
F
oreign Object Ingress
IP XY
(2
nd
digit Y)
Protection Against
P
enetration by Water
2 1
2.5 mm dia. 0 Not protected
4
1.0 mm dia. 0 Not protected
SECULIFE ST BASE(25)
:
Housing with antimicrobial properties in
accordance with the JIS-Standard Z
2801:2000