4 Frequency Generator (positive square-wave pulses) [Hz]
Voltage and frequency can be set independent of each other for
frequency generators.
The output signal is a square wave. Resistance of the connected
circuit should not be any less than 1 k.
Connect the device to be calibrated with the measurement
cable in the same way as specified for the voltage simulator.
Select the HZ calibration function with the rotary switch.
Switch the calibrator on by pressing the ON / OFF | LIGHT
key.
Set the voltage range (300 mV, 3 V, 10 V or 15 V):
Switch to the voltage range menu [
select range] by pressing the
SELECT | ESC key twice. Select the desired voltage range
with the  keys. Acknowledge your selection with
OUT | ENTER. The display is switched to the voltage
amplitude entry window.
Set voltage amplitude (0 15 V):
Select the digit to be changed with the keys, and change
the respectively selected digit with the keys.
Acknowledge your selection with OUT | ENTER. The display is
switched to the frequency entry window, but the selected
voltage amplitude still appears in the auxiliary display.
Set frequency (1 1000 Hz):
ON indicates: Voltage is applied directly to the output using the se-
lected frequency!
Select the digit to be changed with the keys, and change
the respectively selected digit with the keys.
The output can be deactivated with the OUT | ENTER key
[
out.off], or activated once again.
Note!
The following error messages are possible:
HiCurr” (high current – current at overload limit) where
I
max.
=18mA,0ut 0l” and 3 acoustic signals (out of
limit – limit value exceeded) where I > 27 mA; the simulator
is switched off.
Attention!
!
No interference voltage may be applied to the calibrator
jacks in this operating mode.
The calibrator is protected against brief application of a
large interference voltage with a replaceable fuse in the
event of operator error (see section 12.3).
Abbreviated Instructions
Set the voltage range (starting from frequency display).
select range: 15 V 60 mV
Set voltage amplitude (starting from frequency display).
000.00 V  
Set frequency.
0000.0 Hz  
SELECT
ESC
SELECT
ESC
SELECT
ESC
OUT
ENTER