Instructions / Assembly

Cleanup
22 3A3208B
19. Turn Prime/Spray valve down to
PRIME position.
20. Turn ON/OFF switch to OFF position.
Cleaning InstaClean
Fluid Filter (ProX only)
The InstaClean Fluid Filter prevents particles
from entering paint hose. After each use,
remove and clean it to ensure peak
performance.
1. Perform Pressure Relief Procedure,
page 13.
2. Disconnect airless spray hose (A) from
sprayer.
3. Unscrew outlet fitting (B).
4. Remove InstaClean Fluid Filter (C).
5. Check InstaClean Fluid Filter (C) for
debris. If needed, clean filter with water
or flushing fluid and a soft brush.
a. Install closed (square) end of
InstaClean Fluid Filter (C) in
sprayer.
b. Screw outlet fitting (B) into sprayer.
6. Tighten outlet fitting and reconnect hose
(A) to sprayer. Use two wrench to tighten
securely.
Clean the Gun
1. Clean gun fluid filter with water or
flushing fluid and a brush every time you
flush the system. Replace gun filter if
damaged.
2. Remove spray tip and tip guard and
clean with water or flushing fluid and a
brush.
3. Wipe paint off outside of gun using a soft
cloth moistened with water or flushing
fluid.
ti27120a
C
B
A
t
ti
27179a
ti27122a
ti27494a
ti27152a