Operating Guide

Start Up
14 3A6419B EN
Start Up
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1. Turn ON/OFF switch to the OFF
position.
2. Engage the trigger lock. Always engage
the trigger lock when sprayer is stopped
to prevent the gun from being triggered
accidentally.
3. Turn pressure control knob to lowest
setting.
4. Put Drain Tube into a waste pail and
turn Prime/Spray Valve down to PRIME
position to relieve pressure.
5. Hold the gun firmly to a pail. Point gun
into pail. Disengage the trigger lock and
trigger the gun to relieve pressure.
6. Engage the trigger lock.
7. If you suspect that pressure has not
been fully relieved, see Blockages,
page 17.
NOTE: Leave Prime/Spray Valve in the
PRIME position until you are ready to spray.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid, such as skin injection or splashed
fluid, follow the Pressure Relief
Procedure whenever sprayer is stopped
and before sprayer is cleaned or checked,