User Manual

Preparation
3A3258C 9
Preparation
Pressure Relief Procedure
Follow the Pressure Relief
Procedure whenever you see this
symbol.
1. Turn ON/OFF switch to the OFF
position. Wait 7 seconds for power to
dissipate.
2. On the RTX1400si, trigger gun into
material hopper.
3. On the RTX2000pi, open air control
valve.
4. Open gun prime valve.
Grounding
This sprayer includes a ground wire with an
appropriate ground contact. The plug must
be plugged into an outlet that is properly
installed and grounded in accordance with all
local codes and ordinances.
Do not modify the plug provided; if it does not
fit the outlet, have the proper outlet installed
by a qualified electrician.
Power Requirements
100-120V units require 100-120 VAC, 50/60
Hz, 12 or
15A, 1 phase.
Extension Cords
Use an extension cord with an undamaged
ground contact. If an extension cord is
necessary, use a 3-wire, 12 AWG (2.5 mm
2
)
minimum.
This equipment stays pressurized until
pressure is manually relieved. To help
prevent serious injury from pressurized
fluid or splashed fluid follow the Pressure
Relief Procedure whenever sprayer is
stopped and before sprayer is cleaned or
checked, and before equipment is
serviced.
ti27340a
The equipment must be grounded to
reduce the risk of static sparking and
electric shock. An electric or static spark
can cause fumes to ignite or explode. An
improper ground can cause electric shock.
A good ground provides an escape wire for
the electric current.
ti27341a