Full Product Manual

Cleanup
3A4967E 25
Cleaning HVLP Edge II Gun
1. Remove retaining ring and air cap.
2. Trigger the gun and remove fluid nozzle
from gun.
NOTE: Edge II Plus guns contain air cap
guide and spring held in place by fluid nozzle.
Upon removal of fluid nozzle, set aside air
cap guide and spring.
3. Move trigger slide from SPRAY position
(A) to NEEDLE REMOVAL position (B).
4. Remove needle from front of gun.
NOTICE
Solvents, such as lacquer thinner, can
damage parts of the HVLP Edge II gun. Do
NOT immerse parts of the HVLP Edge II
gun in solvent.
NOTICE
Trigger the gun whenever removing or
installing the fluid nozzle. This prevents the
fluid nozzle and needle seating surfaces
from being damaged.
ti30850a
ti30851a
SPRAY
Position
NEEDLE
REMOVAL
Position
A
B
ti30852a