Product Manual

Start Up
3A7656A 15
Fill Spray Gun and Airless
Hose
1. Hold Spray Gun against grounded metal
waste bucket. Point Spray Gun into
waste bucket.
a. Disengage Trigger Lock.
b. Pull and hold Spray Gun trigger.
c. Turn Prime/Spray Valve horizontal
to SPRAY position.
d. Turn ON/OFF Switch to ON
position.
2. Trigger Spray Gun into waste bucket
until
only disinfectant comes out.
3. Release trigger. Engage Trigger Lock.
4. Inspect Airless Hose connections for
leaks. If leaks occur, perform Pressure
Relief Procedure, page 11, then tighten
all fittings and repeat Start Up. If there
are no leaks, continue with the next step.
5. Clip Drain Tube to Suction Tube.
NOTE: W
hen motor stops, sprayer is ready to
spray disinfectant. If motor continues to run,
sprayer is not properly primed, repeat Fill
Pump and Fill Spray Gun and Airless
Hose, pages 14 and 15.
High-pressure spray is able to inject toxins
into the body and cause serious bodily
injury. Do not stop leaks with hand or rag.