Manual

2002 Top Dry Service School
16
SOFTWARE: SERIES 2000 AUTOFLOW HEATER BOARD
VERSION: 1.00
RELEASE DATE: OCTOBER 20, 1997
1.) When the three fan autoflow was introduced some of the rural
drying centers were having problems dealing with copious
amounts of initation current. The other problem complicating
this precarious situation is that all fans must start
simultaneously in order to prevent the last fan from rotating
backwards. In order to deal in the most efficient manner with
both of the above stated problems we implemented a soft start
scenario which provides a 66% reduction in startup current.
*********************************************************************
SOFTWARE: SERIES 2000 AUTOFLOW HEATER BOARD
VERSION: 0.05
RELEASE DATE: 1996
THIS WAS THE FIRST VERSION RELEASED FOR CUSTOMER OPERATION.
NOTE: remember to always do a hard reboot after installing new software to the display board or the IO
board. Shut off all gas valves when installing new software in all burners.
Software revisions
Current Top Dry Software
Top Dry Series 2000 Autoflow-
Display Computer Board – Version 2.13
Heater Computer Board – Version 1.10
Input / Output Board – Version 1.07
Top Dry Series 2000 Batch Heater-
Series 2000 Batch – version .30